Long-term moisture barrier performance of liquid crystal polymer for implantable medical electronics
Brianna ThieleniD, Christopher Pulicken, Eyal Aklivanh, Philip N. SabesiD, Milan Cvitkovic
Abstract
1.Liquid crystal polymer (LCP) is commonly used in the electronics industry due to its favorable dielectric, thermal, and insulative properties. It has recently gained popularity in the medical field for these same reasons, as well as its biocompatibility, moisture barrier properties, and ability to be microfabricated into thin film flexible circuits or flex PCBs. While polymers such as polyimide and Parylene C remain more common for electronics encapsulation and flexible circuit fabrication due to their relatively lower barriers to adoption and history of use, LCPs superior moisture barrier performance and low risk of delamination make it a promising material for chronic use in medical devices. In this work, the moisture barrier properties of LCP are evaluated using in vitro accelerated aging over 59-61 weeks at 65-68 {degrees}C, corresponding to an equivalent implanted lifetime of 8.1 and 9.4 years at 37 {degrees}C for each of two sample groups: LCP as an electronics encapsulant and as a flexible circuit substrate. In the encapsulation group, relative humidity inside an encapsulation pocket was monitored over time with no noticeable change in humidity throughout the measurement period. In the flexible circuit group, impedance of laminated interdigitated electrodes was monitored over time, with an average decrease to 44% of the initial impedance value across all successful samples due to the moisture absorption of the LCP, which has remained stable for the latter half of testing. In both groups, no delamination was observed. These findings demonstrate that LCP is a viable moisture barrier for electronics in implanted medical devices for an estimated equivalent lifetime of at least 8.1 years.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On the Stability of Silicone-Encapsulated CMOS ICs for Active Implantable Devices: 4.3 Years of Accelerated Life Testing
Ahmad Shah Idil, Callum A. Lamont, … Nick Donaldson·bioRxiv·May 21, 2025
- Longevity of Implantable Silicon-ICs for Emerging Neural Applications: Evaluation of Bare Die and PDMS-Coated ICs After Accelerated Aging and Implantation Studies
Kambiz Nanbakhsh, Ahmad Shah Idil, … Vasiliki Giagka·bioRxiv·Mar 6, 2024
- Long-Lasting Electrohydrodynamically Printed Transparent Soft Microelectrode for Implantable Biointerfaces
Hyeongjin Jo, Gaeun Lee, … Kyungjin Kim·Advanced Functional MaterialsPeer-reviewed·Sep 10, 2026
- 3D Printable High Performance Conducting Polymer Hydrogel for All-Hydrogel Bioelectronics
- Implantable electrical stimulation bioreactor with liquid crystal polymer based electrodes for enhanced bone regeneration at mandibular large defects in rabbit
C. Kim, H. J. Yang, … S. J. Hwang·bioRxiv·Jan 3, 2019
- Analytical characterization of Parylene-C degradation mechanisms on Utah arrays: evaluation of in vitro Reactive Accelerated Aging model compared to multiyear in vivo implantation
R. Caldwell, M. G. Street, … L. Rieth·bioRxiv·Aug 24, 2019