MetabolitesMolecular BiologyPeer-reviewed journal article
Methodological assessment of PDMS passive sampling for skin VOC collection across body sites
Seibi KobaraiD, Min Huang, Rizky IlhamsyahiD, Daniel R. StrukiD, John Dimandja, Peter J. HeskethiD, Daniela ChanciiD, Chase M. FensoreiD, Carmen C. Polito, Rishikesan KamaleswaraniD, Annette M. EsperiD
Abstract
Background/ObjectivesPolydimethylsiloxane (PDMS) is a non-invasive and versatile material often used for non-invasive collection of skin-emitted volatile organic compounds (VOCs), with potential applicability in acute and pre-critical care settings. However, most existing PDMS-based methodologies rely on extensive sample preparation and environmental control, limiting their feasibility in time-sensitive clinical contexts. MethodsWe conducted a proof-of-concept pilot study in four healthy volunteers to evaluate whether a simplified skin-contact PDMS sampling procedure can capture detectable VOCs and preserve individual-level variation. PDMS strips were applied directly to the skin with minimal preparation, and collected VOCs were analyzed using gas chromatography-mass spectrometry. Donor-associated variability was assessed using Bray-Curtis dissimilarity, and variability in VOC detection was evaluated across body sites. ResultsSkin-contact PDMS sampling detected 160 VOCs across four participants. The mean within-donor Bray-Curtis dissimilarity was 0.308, compared with a mean between-donor dissimilarity of 0.347. Preliminary permutation testing showed distinguishable donor profiles (p-value = 0.004). VOC detection variability differed across body sites, with lower coefficients of variation at the forehead, neck, and wrist than at the ankle. ConclusionsUnder simplified sampling conditions, skin-contact PDMS captured individual-associated VOC profiles with lower within-donor variability than between-donor variability. These findings support the feasibility of PDMS-based skin VOC sampling in minimally controlled settings. Further validation in larger and clinically relevant cohorts is warranted to assess the utility of PDMS-sampled skin VOCs as potential biomarkers for early disease detection.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- top 36%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Non-Invasive Skin Sampling Detects Systemically Administered Drugs in Humans
M. Panitchpakdi, K. C. Weldon, … S. M. Tsunoda·bioRxiv·Nov 22, 2021
- Inter-laboratory comparison of plant volatile analyses in the light of intra-specific chemodiversity
S. Eckert, E. J. Eilers, … C. Mueller·bioRxiv·Feb 15, 2023
- Determination of chemical partitioning in vehicles using a skin surrogate for dermal absorption model refinement.
Ruth U. Pendlington, David Sanders, … Hequn Li·bioRxiv·May 29, 2025
- The oral microbiome and its effect on exhaled breath volatile analysis - the elephant in the room
Lorenzo Salvatore Petralia, Anesu Chawaguta, … Daniel Sanders·Journal of Breath ResearchPeer-reviewed·Jul 28, 2025
- Evaluation of solvents used for fabrication of microphysiological systems
X. Wen, S. Takahashi, … K.-i. Kamei·bioRxiv·Mar 24, 2021
- Interventional breath analysis reveals oral microbial conversion of 1,2-Propanediol into Propanal and 1-Propanol
Anesu Chawaguta, Daniel Sanders, Lorenzo Salvatore Petralia·bioRxiv·Nov 9, 2026