bioRxivPhysiologyPreprint
Limitations of renal arterial hemodynamic measures as candidate biomarkers of renal sympathetic innervation
Carson Dettmer, Alicia M. SchilleriD, Irving H. ZuckeriD, Yiannis S. ChatzizisisiD, Hanjun WangiD, Peter Ricci PellegrinoiD
Abstract
Introduction: The key role of maladaptive renal sympathetic activation in hypertension has led to the development of catheter-based renal denervation therapies. Unfortunately, the lack of practical physiological biomarkers impairs patient selection and prevents intraprocedural feedback for renal denervation. Methods: We tested whether renal arterial hemodynamic measures and the beat-to-beat variability of these measures reflect renal sympathetic innervation in two tightly controlled preclinical models of renal denervation. Bilateral renal hemodynamic data were obtained from ten conscious unilaterally denervated rabbits and ten anesthetized unilaterally denervated pigs that subsequently underwent stepwise catheter-based radiofrequency denervation of the contralateral kidney. Renal arterial mechanics were assessed by quantification of wave speed and input impedance modulus and phase shift. Variability was quantified as the within-recording standard deviation of each metric when measured on a beat-to-beat basis. Results: Wave speed trended down after surgical denervation in rabbits (P = 0.054) but not swine (P = 0.57); wave speed variability was unchanged in both models. Renal arterial input impedance modulus was not significantly affected by surgical denervation. Surgical renal denervation increased input impedance phase shift in rabbits (P = 0.0048) but not in swine (P = 0.85). The beat-to-beat variability of modulus did not differ significantly between innervated and surgically denervated kidneys in either species. Surgical renal denervation decreased phase shift variability in swine (P = 0.0048) but not rabbits. The difference in phase shift variability between kidneys in swine was eliminated after a single round of branch-vessel ablation (P = 0.42). Discussion: Renal arterial wave speed, input impedance, and their beat-to-beat variability did not consistently or dose-dependently reflect renal sympathetic innervation in these models. These findings argue against their use as direct physiological surrogates for renal sympathetic outflow.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Sympathetic Vasomotion Reflects Catheter-based Radiofrequency Renal Denervation
Peter Ricci Pellegrino, Irving H. Zucker, … Alicia M. Schiller·HypertensionPeer-reviewed·May 27, 2025
- Enhancing the Clinical Utility of Renal Denervation Through Efficient Physiologic Monitoring
Kari Shad, Alicia M. Schiller, … Peter Ricci Pellegrino·bioRxiv·Sep 29, 2026
- Sex-specific dichotomy of chronic mild stress effects on blood pressure and longitudinal measurements of renal sympathetic nerve activity: are females really protected?
Dragana Komnenov, Yaaqub Uthman, … Christopher Todd Banek·bioRxiv·Aug 10, 2026
- Sympathetic vasomotion as an early marker of hemorrhage
Peter Ricci Pellegrino, Alicia M. Schiller, … Hanjun Wang·Frontiers in PhysiologyPeer-reviewed·Nov 27, 2025
- Impact of angiotensin-receptor blockers on intrarenal renin-angiotensin system activity in hypertension: A PK/PD modelling study
- Natriuretic Peptide Augmentation Attenuates Renin Cell Hyperactivation and Afferent Arteriolar Hypertrophy During Long-Term Renin-Angiotensin System Inhibition
Tomomi Shiiya, Hirofumi Watanabe, … Suguru Yamamoto·bioRxiv·Jul 24, 2026