Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches
H. J. Good, O. C. Sehl, J. J. Gevaert, B. Yu, M. A. Berih, S. A. Montero, C. M. Rinaldi-Ramos, P. J. Foster
Abstract
PurposeMagnetic particle imaging (MPI) is being explored in biological contexts that require accurate and reproducible quantification of superparamagnetic iron oxide nanoparticles (SPIONs). While many groups have focused on improving imager and SPION design to improve resolution and sensitivity, few have focused on improving quantification and reproducibility of MPI. The aim of this study was to compare MPI quantification results by two different systems and the accuracy of SPION quantification performed by multiple users at two institutions. ProceduresSix users (3 from each institute) imaged a known amount of Vivotrax+ (10 g Fe), diluted in a small (10 L) or large (500 L) volume. These samples were imaged with or without calibration standards in the field of view, to create a total of 72 images (6 users x triplicate samples x 2 sample volumes x 2 calibration methods). These images were analyzed by the respective user with two region of interest (ROI) selection methods. Image intensities, Vivotrax+ quantification, and ROI selection was compared across users, within and across institutions. ResultsMPI imagers at two different institutes produce significantly different signal intensities, that differ by over 3 times for the same concentration of Vivotrax+. Overall quantification yielded measurements that were within {+/-} 20% from ground truth, however SPION quantification values obtained at each laboratory were significantly different. Results suggest that the use of different imagers had a stronger influence on SPION quantification compared to differences arising from user error. Lastly, calibration conducted from samples in the imaging field of view gave the same quantification results as separately imaged samples. ConclusionsThis study highlights that there are many factors that contribute to the accuracy and reproducibility of MPI quantification, including variation between MPI imagers and users, despite pre-defined experimental set up, image acquisition parameters, and ROI selection analysis.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- MPI region of interest (ROI) analysis and quantification of iron in different volumes
O. C. Sehl, B. Tiret, … P. J. Foster·bioRxiv·Apr 10, 2022
- Comparative Evaluation of Commercial Iron Oxide Particles for Magnetic Particle Imaging Using Relaxometry and Image-Based Metrics
Bijita Neupane, Paula J. Foster·bioRxiv·Sep 22, 2026
- Advances in magnetic particle imaging: evaluating magnetic microspheres and optimized acquisition parameters for high sensitivity cell tracking
Samantha Flood, Paula J. Foster·Frontiers in ImagingPeer-reviewed·Jul 24, 2025
- Development of Magnetic Particle Imaging (MPI) for Cell Tracking and Detection
K. P. Melo, A. V. Makela, … P. J. Foster·bioRxiv·Jul 12, 2020
- Particle interactions and their effect on magnetic particle imaging and spectroscopy
L. Moor, S. Scheibler, … F. H. L. Starsich·bioRxiv·Oct 29, 2021
- Evaluating Labelling Efficiency of Commercial SPIONs in Mesenchymal Stem/Stromal Cells for Magnetic Particle Imaging Applications
Serbay Özkan, Elena Ureña-Horno, … Patricia A. Murray·bioRxiv·Aug 2, 2025