bioRxivBioinformaticsPreprint
Telomere-to-Telomere Phased Genome Assembly Using HERRO-Corrected Simplex Nanopore Reads
Dominik StanojevićiD, Dehui LiniD, Sergey NurkiD, Paola Flórez de SessionsiD, Mile ŠikićiD
Abstract
Telomere-to-telomere phased assemblies have become the norm in genomics. To achieve these for diploid and even polyploid genomes, the contemporary approach involves a combination of two long-read sequencing technologies: high-accuracy long reads, e.g. Pacific Biosciences (PacBio) HiFi or Oxford Nanopore (ONT) Duplex reads, and ultra-long ONT Simplex reads. Using two different technologies increases the cost and the required amount of genomic DNA. Here, we show that comparable results are possible using error correction of ultra-long ONT Simplex reads and then assembling them using state-of-the-art de novo assembly methods. To achieve this, we have developed the deep learning-based HERRO framework, which corrects ONT Simplex reads while carefully preserving differences in related genomic sequences. Taking into account informative positions that differentiate the haplotypes or genomic repeat copies, HERRO achieves an increase of read accuracy of up to 100-fold for diploid human genomes. By combining HERRO with Verkko assembler, we achieve high contiguity on several human genomes by reconstructing many chromosomes telomere-to-telomere, including chromosomes X and Y. HERRO supports both R9.4.1 and R10.4.1 ONT Simplex reads and generalizes well to other species. These results provide an opportunity to reduce the cost of genome sequencing and use corrected ONT reads to analyze more complex genomes with different levels of ploidy or even aneuploidy.
Abstract summary
Claude Opus 5.5 · xhigh effort · 18 Oct 2026 · from the abstract · CC BY-ND 4.0
Deep-learning correction of ultra-long nanopore Simplex reads lifts read accuracy up to 100-fold and yields phased telomere-to-telomere human assemblies without a second sequencing technology.
Phased telomere-to-telomere assemblies currently combine two long-read technologies, a high-accuracy one such as PacBio HiFi or ONT Duplex plus ultra-long ONT Simplex, which increases cost and required genomic DNA. If Simplex reads can be corrected well enough to assemble on their own, the second sequencing technology becomes unnecessary.
Key results
ShownCorrecting ultra-long Simplex reads raises their accuracy by a large factor while leaving intact the differences that separate haplotypes and repeat copies.
Reported as an increase of up to 100-fold on diploid human genomes, driven by taking informative haplotype- and repeat-distinguishing positions into account; no competing correction tool or baseline accuracy value is named. · Abstract
SuggestedAssemblies built from the corrected Simplex reads alone span many chromosomes end to end, including the sex chromosomes.
HERRO combined with the Verkko assembler on several human genomes reconstructed many chromosomes telomere-to-telomere, among them X and Y; the abstract gives no genome count, chromosome count or contiguity statistic. · Abstract
ClaimedThe correction model covers two nanopore chemistries and is said to carry over to other organisms and ploidy levels.
Support for R9.4.1 and R10.4.1 ONT Simplex reads is stated; generalisation to other species, and the prospect of handling polyploid or aneuploid genomes, is asserted without an example or figure in the abstract. · Abstract
Methods, data and reproducibility
HERRO is a deep learning framework that corrects ultra-long Oxford Nanopore Simplex reads while weighting the positions that tell haplotypes or repeat copies apart, so genuine sequence differences are not smoothed away. Corrected reads were then passed to the Verkko assembler, and results were judged by read accuracy on diploid human genomes and by assembly contiguity.
- Diploid human genomes sequenced with ultra-long ONT Simplex reads, used to measure correction accuracy · human
- Human genomes assembled from corrected reads with Verkko · human · n = several human genomes
- Methods & tools
- HERRO, Verkko, Oxford Nanopore Simplex sequencing (R9.4.1, R10.4.1)
Limitations (2)
- Only read accuracy is quantified, as an upper bound of up to 100-fold; no assembly statistics, quality values or counts of completed chromosomes appear, and no assembly from HiFi or Duplex data is compared against. · noted in this summary
- Claims about other species and about polyploid or aneuploid genomes come with no example organism or measurement in the text available. · noted in this summary
Read this if you assemble phased genomes from nanopore data and want to know whether corrected Simplex reads can replace a second high-accuracy library.
- Citations
- 62
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Gapless assembly of complete human and plant chromosomes using only nanopore sequencing
Sergey Koren, Zhigui Bao, … Adam M. Phillippy·Genome ResearchPeer-reviewed·Nov 1, 2024
- Verkko2: Integrating proximity ligation data with long-read De Bruijn graphs for efficient telomere-to-telomere genome assembly, phasing, and scaffolding
Dmitry Antipov, Mikko Rautiainen, … Sergey Koren·Genome ResearchPeer-reviewed·Jul 1, 2025
- Efficient near telomere-to-telomere assembly of Nanopore Simplex reads
Haoyu Cheng, Han Qu, … Heng Li·NaturePeer-reviewed·Feb 4, 2026
- An efficient error correction and accurate assembly tool for noisy long reads
Jiang Yong Hu, Zhuo Wang, … Sheng Wang·bioRxiv·Mar 9, 2023
- Chasing perfection: validation and polishing strategies for telomere-to-telomere genome assemblies
Ann M. Mc Cartney, Kishwar Shafin, … Arang Rhie·Nature MethodsPeer-reviewed·Mar 31, 2022
- Verkko: telomere-to-telomere assembly of diploid chromosomes
Mikko Rautiainen, Sergey Nurk, … Sergey Koren·Nature BiotechnologyPeer-reviewed·Feb 16, 2023