bioRxivMicrobiology
Disinfection performance of a drinking water bottle system with a UVC LED cap against waterborne pathogens and heterotrophic contaminants
R. M. Mariita, S. A. Blumenstein, C. M. Beckert, T. Gombas, R. V. Randive
Abstract
BackgroundThe purgaty One systems (cap+bottle) are portable stainless-steel water bottles with ultraviolet subtype C (UVC) disinfection capability. This study examines the bottle design, verifies disinfection performance against Escherichia coli, Pseudomonas aeruginosa, Vibrio cholerae and heterotrophic contaminants and addresses the public health relevance of heterotrophic bacteria. MethodsBottles were inoculated with bacterial strains and disinfection efficacy examined using colony forming unit (CFU) assay. The heterotrophic plate count (HPC) method was used to determine the disinfection performance against environmental contaminants at day 0 and after 3 days of water stagnation. All UVC irradiation experiments were performed under stagnant conditions to confirm that the preset application cycle of 55 seconds offers the desired disinfection performance under worst case condition. To determine effectiveness of purgaty One systems (cap+bottle) in disinfection, inactivation efficacy or log reduction value (LRV) was determined using bacteria concentration between UVC ON condition and controls (UVC OFF). The study utilized the 16S rRNA gene for isolate characterization by identifying HPC bacteria to confirm if they belong to groups that are of public health concern. ResultsPurgaty One systems fitted with Klaran UVC LEDs achieved 99.99% inactivation (LRV4) efficacy against E. coli and 99.9% inactivation (LRV3) against P. aeruginosa, V. cholerae and heterotrophic contaminants. Based on the 16S rRNA gene analyses, the study determined that the identified HPC isolates enriched by UVC irradiation are of rare public health concern. ConclusionThe bottles satisfactorily inactivated the target pathogenic bacteria and HPC contaminants even after 3 days of water stagnation.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluation of the virucidal efficacy of Klaran UVC LEDs against surface dried norovirus
R. Mariita, A. C. Wilson Miller, R. Randive·bioRxiv·Apr 28, 2021
- Development of a UVGI System and Evaluation of Germicidal Potential Against Biofilm-Forming Bacteria and Fungi Under Controlled Laboratory Conditions
Bindu Sadanandan, Shyam Sunder, … Kalidas Shetty·bioRxiv·Mar 31, 2026
- Experimental Investigation Of Pulse Sterilization Of Pathogens
V. I. Chumakov, M. Ostryzhnyi, … A. Tarasevich·bioRxiv·Nov 25, 2021
- Effect of germicidal short wave-length ultraviolet light on the polyphenols, vitamins, and microbial inactivation in highly opaque apple juice
A. V. Scales Akwu, A. Patras, … M. J. Vergne·bioRxiv·Jul 29, 2022
- A comprehensive evaluation of ultraviolet irradiation at 254 nm and 222 nm in inactivating human noroviruses on surfaces
Hong Bai, Malcolm Turk Hsern Tan, … Dan Li·bioRxiv·Dec 18, 2025
- Defining Operational UV-C Dose Requirements for Autonomous Disinfection of Clinically Relevant Pathogens Across Healthcare and High-Touch Surfaces
Isaac Kong Fan Wu, Neel R. Vajaria, … Stephen Dominic Barr·bioRxiv·Aug 27, 2026