Defining Operational UV-C Dose Requirements for Autonomous Disinfection of Clinically Relevant Pathogens Across Healthcare and High-Touch Surfaces

Isaac Kong Fan Wu, Neel R. Vajaria, Luz Victoria Stam Viruega, Evelyn Wisebourt, Paul Solis-Reyes, Kanghan Ryu, Elijah R Ilasin, Amy Yang Shi, Nicole J. Friesen, Khandaker Atkia Fariha, Stephen Dominic BarriD

Abstract

Background: Autonomous ultraviolet-C (UV-C) disinfection systems are increasingly used to supplement manual environmental cleaning, yet evidence-based guidance defining pathogen-specific UV-C dose requirements across representative surfaces remains limited. Aim: To characterize operational UV-C dose requirements for clinically relevant pathogens across diverse high-touch and healthcare surfaces and determine how experimentally derived microbial inactivation can inform operational exposure parameters. Methods: SARS-CoV-2, adenovirus, Pseudomonas aeruginosa, Staphylococcus aureus, Klebsiella pneumoniae, Enterococcus faecalis, Candida auris, and Clostridioides difficile spores were exposed to defined UV-C doses on representative high-touch materials or stainless steel under standardized conditions, including a 10% fetal bovine serum organic soil challenge. Microbial inactivation was quantified by viable recovery. Dose-response analysis and operational modelling were used where supported by the experimental data. Findings: UV-C exposure significantly reduced viable recovery of all pathogens, with substantial differences in the exposure conditions associated with microbial inactivation. SARS-CoV-2 exhibited substantial inactivation at doses as low as 2.6 mJ/cm2, whereas the highest evaluated doses were 1,800 mJ/cm2 for C. difficile spores and 3600 mJ/cm2 for C. auris. For C. auris, multi-dose data estimated that approximately 1,410 mJ/cm2 was associated with a 2-log10 reference reduction, enabling distance-dependent exposure-time predictions. Conclusion: Experimentally quantified UV-C exposures produced substantial microbial inactivation across diverse pathogen classes and surfaces. Integrating delivered dose with microbial reduction provides a quantitative framework for translating laboratory efficacy into operational parameters for autonomous UV-C disinfection.

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISRuetalo '20Garg '23Koutras '22Angel '25Koutras '23Jureka '21
77% semantic matchMicrobiology
N. Ruetalo, R. Businger, M. Schindler·bioRxiv·Sep 22, 2020