bioRxivMicrobiologyPreprint
Effect of germicidal short wave-length ultraviolet light on the polyphenols, vitamins, and microbial inactivation in highly opaque apple juice
A. V. Scales Akwu, A. Patras, B. Pendyala, A. H. Kurup, F.-C. Chen, M. J. Vergne
Abstract
The aim of this investigation was to study the efficacy of UV-C light emitting diode system (LED) operating at 263 nm for the inactivation of Listeria monocytogenes and Escherichia coli O157:H7. Specified concentrations of bacteria were inoculated in apple juice and irradiated at the designated UV doses of 0 to 15 mJ{middle dot}cm-2. In addition, UV irradiation doses ranging from 0 to 160 mJ{middle dot}cm-2 were also delivered to apple juice and polyphenols and vitamins were profiled. LC-MS/MS analysis was conducted to assess the stability of polyphenols or vitamins in UV-C exposed apple juice. The polyphenol and vitamin results demonstrated that UV-C irradiation in apple juices at relevant commercial UV doses induced significant reductions in the concentrations of selected polyphenols and vitamins, p0.95) and low RMSE values. The D10 values of 4.16 and 3.84 mJ{middle dot}cm-2 were obtained from the inactivation of Escherichia coli, and Listeria monocytogenes in apple juice. The results from this study imply that adequate log reduction of pathogens is achievable in apple juice and suggest significant potential for UV-C treatment of other liquid foods.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Performance Assessment of an Ultraviolet Light Emitting Semi-Conductor Device in Treating Apple Juice: Microbial Inactivation and Biochemical Assessment Study
A. V. Scales Akwu, A. Patras, … M. J. Vergne·bioRxiv·Oct 11, 2022
- Degradation of boscalid, pyraclostrobin, fenbuconazole, and glyphosate residues by an advanced oxidative process utilizing ultraviolet light and hydrogen peroxide
B. Skanes, J. Ho, … R. Prosser·bioRxiv·Nov 13, 2020
- Disinfection performance of a drinking water bottle system with a UVC LED cap against waterborne pathogens and heterotrophic contaminants
R. M. Mariita, S. A. Blumenstein, … R. V. Randive·bioRxiv·Jun 2, 2021
- Development of a UVGI System and Evaluation of Germicidal Potential Against Biofilm-Forming Bacteria and Fungi Under Controlled Laboratory Conditions
Bindu Sadanandan, Shyam Sunder, … Kalidas Shetty·bioRxiv·Mar 31, 2026
- Preclinical safety evaluation of continuous UV-A lighting in an operative setting
Rachael E. Guenter, Rui Zheng-Pywell, … John Bart Rose·PLoS ONEPeer-reviewed·Nov 17, 2023
- Inactivation effect and damage of multi-irradiance by UVCLED on Acinetobacter baumannii