bioRxivBioengineering
Applications of a Novel Reciprocating Positive Displacement Pump in the Simulation of Pulsatile Arterial Blood Flow
Abstract
Pulsatile arterial blood flow plays an important role in vascular system mechanobiology, especially in the study of mechanisms of pathology. Limitations in cost, setup time, sample size, and control across current in-vitro and in-vivo methods prevent future exploration of novel treatments. Presented is the verification of a novel reciprocating positive displacement pump aimed at resolving these issues through the simulation of human ocular, human fingertip and skin surface, human cerebral, and rodent spleen organ systems. A range of pulsatile amplitudes, frequencies, and flow rates were simulated using pumps made of 3D printed parts incorporating a tubing system, check valve and proprietary software. Volumetric analysis of 430 total readings across a flow range of 0.025ml/min to 16ml/min determined that the pump had a mean absolute error and mean relative error of 0.041 ml/min and 1.385%, respectively. Linear regression of flow rate ranges yielded R2 between 0.9987 and 0.9998. Waveform analysis indicated that the pump could recreate accurate beat frequency for flow ranges above 0.06ml/min at 70BPM. The verification of accurate pump output opens avenues for the development of novel long-term in-vitro benchtop models capable of looking at fluid flow scenarios previously unfeasible, including low volume-high shear rate pulsatile flow.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Testing and Validation of Reciprocating Positive Displacement Pump for Benchtop Pulsating Flow Model of Cerebrospinal Fluid Production and Other Physiologic Systems
A. Faryami, A. Menkara, … D. Viar·PLOS ONEPeer-reviewed·May 12, 2022
- Design and Validation of an Open Loop Controlled Positive-Displacement Pump for Vascular Flow Modelling
T. O'Brien·bioRxiv·Feb 17, 2023
- Adaptation of peristaltic pumps for laminar flow experiments
J. Abello, Y. Y. Yien, A. N. Stratman·bioRxiv·Oct 17, 2021
- Adaptable pulsatile flow generated by quantitative imaging of stem-cell derived cardiomyocytes for disease modeling
T. Qian, D. A. Gil, … M. C. Skala·bioRxiv·Mar 20, 2020
- Realistic boundary conditions for perivascular pumping in the mouse brain reconcile theory, simulation, and experiment
Antonio Ladrón-de-Guevara, Jessica K. Shang, … Douglas H. Kelley·bioRxiv·Jul 2, 2020
- Three-Dimensional Fluid-Structure Interaction Reveals Trade-offs Among Oxygen Delivery, Shear, and Washout in Pediatric Roller-Pump Cardiopulmonary Bypass
Yunpeng Tu, Yi‐Ting Yeh, … Christina L. Greene·bioRxiv·Oct 28, 2026