ACS OmegaBioengineeringPeer-reviewed journal article
Surfactant-Assisted Colorimetric Signal Enhancement in Paper-Based Glucose Sensing
Dain KangiD, 종호 이, Minwoo Bae, Seokbeom RohiD, Da Yeon CheongiD, Hyungbeen LeeiD, Taeha LeeiD, Gyudo LeeiD
Abstract
Paper-based colorimetric sensors offer a low-cost and accessible platform for point-of-care (POC) analysis, but enzyme activity loss during coating and drying can weaken analytical signals and require high enzyme loadings or complex immobilization procedures. Although surfactants are widely used to improve wettability in paper-based assays, their potential contribution to colorimetric performance beyond these effects remains unclear. Here, we investigated surfactant-assisted colorimetric signal enhancement in a glucose assay implemented on a 96-puddle paper plate (96-PPP) and identified Tween 20 as the most effective surfactant. Its effect on detection performance became more pronounced as glucose oxidase (GOx) loading decreased; at 0.1 mg/mL GOx, Tween 20 lowered the limit of detection (LoD) from 0.113 to 0.034 mg/mL (approximately 3.3-fold) over a working range of 0-5 mg/mL, despite no statistically significant change in the measured contact angle at this loading. Tween 20 had no appreciable effect on the reaction in solution but preserved 95% of the apparent reaction rate constant after drying, compared with 11% without it, and atomic force microscopy (AFM) revealed a more dispersed dried enzyme morphology on mica. Tween 20-containing sensors also showed slower signal decay during repeated wetting-drying cycles and thermal stress, retained 77% (vs 26%) of the response at 400 mM NaCl, and exhibited within-PPP and between-batch coefficients of variation (CVs) below 10% (vs 12.3-19.5%), while maintaining glucose selectivity over potentially interfering molecules. These results indicate that Tween 20 enhances paper-based glucose sensing beyond wettability, in part by retaining enzyme cascade activity during drying, although the contributions of the individual enzymes and the underlying mechanism remain to be established.
- Citations
- 1
- FWCI
- 1.72
- Field percentile
- top 12%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Design, Fabrication, and Theoretical Investigation of a Cost-Effective Laser Printing Based Colorimetric Paper Sensor for Non-Invasive Glucose and Ketone Detection
M. Mukhopadhyay, S. G. Subramanian, … S. DasGupta·bioRxiv·Sep 23, 2021
- Paper-based Sensing of Fucosylated Biological Compounds
F. Enam, T. J. Mansell, … R. Cademartiri·bioRxiv·Oct 30, 2020
- Chitozyme: First Peroxidase-like Activity of Chitosan for Multiplexed Visual Detection of H2O2, Glucose and Lactate on Paper-based Device
Syed Rahin Ahmed, Xuan Weng, Suresh Neethirajan·bioRxiv·Jul 12, 2017
- Covalent conjugation of glucose oxidase on single-walled carbon nanotubes for glucose sensing
Hanxuan Wang, Subhasis Dehury, … Ardemis Anoush Boghossian·bioRxiv·Oct 14, 2024
- Evidence for rapid hydrolysis of shoot-derived sucrose using an ultrasensitive ratiometric Matryoshka-type MGlucoMeter sensor
Yuuma Ishikawa, Nora R. Zöllner, … Wolf Bernd Frommer·The Plant JournalPeer-reviewed·Mar 1, 2026
- Paper based microfluidic aptasensor for food safety
X. Weng, S. Neethirajan·bioRxiv·Jul 12, 2017