Journal of Proteome ResearchBioinformaticsPeer-reviewed journal article
Isobaric labeling update in MaxQuant
Daniela Ferretti, Pelagia KyriakidouiD, Jinqiu XiaoiD, Shamil Z. UrazbakhtiniD, Carlo De Nart, J. CoxiD
Abstract
We present an update of the MaxQuant software for isobaric labeling data and evaluate its performance on benchmark datasets. Impurity correction factors can be applied to labels mixing C- and N-type reporter ions, such as TMT Pro. Application to a single-cell multi-species mixture benchmark shows high accuracy of the impurity-corrected results. TMT data recorded with FAIMS separation can be analyzed directly in MaxQuant without splitting the raw data into separate files per FAIMS voltage. Weighted median normalization, is applied to several datasets, including large-scale human body atlas data. In the benchmark datasets the weighted median normalization either removes or strongly reduces the batch effects between different TMT plexes and results in clustering by biology. In datasets including reference channels, we find that weighted median normalization performs as well or better when the reference channels are ignored and only the sample channel intensities are used, suggesting that the measurement of reference channels is unnecessary when using weighted median normalization in MaxQuant. We demonstrate that MaxQuant including the weighted median normalization performs well on multi-notch MS3 data, as well as on phosphorylation data. MaxQuant is freely available for any purpose and can be downloaded from https://www.maxquant.org/.
- Citations
- 6
- FWCI
- 1.51
- Field percentile
- top 21%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Isobaric matching between runs and novel PSM-level normalization in MaxQuant strongly improve reporter ion-based quantification
Sung‐Huan Yu, Pelagia Kyriakidou, Jürgen Cox·Journal of Proteome ResearchPeer-reviewed·Sep 7, 2020
- Systematic Evaluation of Normalization Approaches in Tandem Mass Tag and Label-Free Protein Quantification Data Using PRONE
Lis Arend, Klaudia Adamowicz, … Tanja Laske·Briefings in BioinformaticsPeer-reviewed·Apr 21, 2025
- IonQuant enables accurate and sensitive label-free quantification with FDR-controlled match-between-runs
Fengchao Yu, Sarah E. Haynes, Alexey I. Nesvizhskii·Molecular & Cellular ProteomicsPeer-reviewed·Jan 1, 2021
- Prior Signal Acquisition Software Versions for Orbitrap Underestimate Low Isobaric Mass Tag Intensities, Without Detriment to Differential Abundance Experiments
Tom S. Smith, Anna Andrejeva, … Kathryn Susan Lilley·ACS Measurement Science AuPeer-reviewed·Mar 9, 2022
- Analysis of isobaric quantitative proteomic data using TMT-Integrator and FragPipe computational platform
Hui-Yin Chang, Yamei Deng, … Alexey I. Nesvizhskii·Nature CommunicationsPeer-reviewed·Mar 2, 2026
- An economic and robust TMT labeling approach for high throughput proteomic and metaproteomic analysis
Marybeth Creskey, Leyuan Li, … Daniel Figeys·PROTEOMICSPeer-reviewed·Dec 18, 2022