ACS Measurement Science AuBioinformaticsPeer-reviewed journal article
Prior Signal Acquisition Software Versions for Orbitrap Underestimate Low Isobaric Mass Tag Intensities, Without Detriment to Differential Abundance Experiments
Tom S. SmithiD, Anna AndrejevaiD, Josie A. ChristopheriD, Oliver M. CrookiD, Mohamed ElzekiD, Kathryn Susan LilleyiD
Abstract
Tandem mass tags (TMT) enable simple and accurate quantitative proteomics for multiplexed samples by relative quantification of tag reporter ions. Orbitrap quantification of reporter ions has been associated with a characteristic notch region in intensity distribution, within which few reporter intensities are recorded. This has been resolved in version 3 of the instrument acquisition software, Tune. However, 53 % of Orbitrap Fusion, Lumos or Eclipse submissions to PRIDE were generated using prior software versions. To quantify the impact of the notch on existing quantitative proteomics data, we generated a mixed species benchmark and acquired quantitative data using Tune versions 2 and 3. Sub-notch intensities are systemically underestimated with Tune version 2, leading to over-estimation of the true differences in intensities between samples. However, when summarising reporter ion intensities to higher level features, such as peptides and proteins, few features are significantly affected. Targeted removal of spectra with reporter ion intensities below the notch is not beneficial for differential peptide or protein testing. Overall, we find the systematic quantification bias associated with the notch is not detrimental for a typical proteomics experiment.
- assay: proteomics
- research focus: benchmarking
- research focus: differential expression
- approach: statistical model
- Citations
- 1
- FWCI
- 0.09
- Field percentile
- 21th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
C. D. Kelstrup, K. Aizikov, … J. V. Olsen·bioRxiv·May 28, 2018
- Direct Measurement of Synchronous Precursor Selection (SPS) Accuracy in Public Proteomics Datasets
Conor Jenkins, Aimee Rinas, Benjamin C. Orsburn·bioRxiv·May 24, 2019
- Evaluation of a prototype Orbitrap Astral Zoom mass spectrometer for quantitative proteomics - Beyond identification lists
Chris Hsu, Nicholas Shulman, … Michael J. MacCoss·Journal of Proteome ResearchPeer-reviewed·Oct 22, 2025
- TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level
Alex N. T. Johnson, Michael Stadlmeier, Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Apr 30, 2021
- Accurate, Sensitive, and Precise Multiplexed Proteomics using the Complement Reporter Ion Cluster
Matthew Sonnett, Eyan Yeung, Martin Wühr·Analytical ChemistryPeer-reviewed·Mar 9, 2018
- Isobaric Tagging and Data Independent Acquisition as Complementary Strategies for Proteome Profiling on an Orbitrap Astral Mass Spectrometer
Xinyue Liu, Shane L. Dawson, … João A. Paulo·Journal of Proteome ResearchPeer-reviewed·Feb 12, 2025