Clinical NeurophysiologyNeurosciencePeer-reviewed journal article
Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements
Karin WestiniD, Christoph PfeifferiD, Lau M. AnderseniD, Silvia RuffieuxiD, Gerald CoorayiD, Alexei KalaboukhoviD, Dag WinkleriD, Martin IngvariD, Justin F. SchneidermaniD, Daniel LundqvistiD
Abstract
Magnetoencephalography (MEG) is an important part of epilepsy evaluations because of its unsurpassed ability to detect interictal epileptiform discharges (IEDs). This ability may be improved by next-generation MEG sensors, where sensors are placed directly on the scalp instead of in a fixed-size helmet, as in todays conventional MEG systems. In order to investigate the usefulness of on-scalp MEG measurements we performed the first-ever measurements of on-scalp MEG on an epilepsy patient. The measurement was conducted as a benchmarking study, with special focus on IED detection. An on-scalp high-temperature SQUID system was utilized alongside a conventional low-temperature "in-helmet" SQUID system. EEG was co-registered during both recordings. Visual inspection of IEDs in the raw on-scalp MEG data was unfeasible why a novel machine learning-based IED-detection algorithm was developed to guide IED detection in the on-scalp MEG data. A total of 24 IEDs were identified visually from the conventional in-helmet MEG session (of these, 16 were also seen in the EEG data; eight were detected only by MEG). The on-scalp MEG data contained a total of 47 probable IEDs of which 16 IEDs were co-registered by the EEG, and 31 IEDs were on-scalp MEG-unique IEDs found by the IED detection algorithm. We present a successful benchmarking study where on-scalp MEG are compared to conventional in-helmet MEG in a temporal lobe epilepsy patient. Our results demonstrate that on-scalp MEG measurements are feasible on epilepsy patients, and indicate that on-scalp MEG might capture IEDs not seen by other non-invasive modalities.
- organism: human
- assay: electronic health records
- research focus: differential expression
- approach: benchmark study
- Citations
- 12
- FWCI
- 1.48
- Field percentile
- top 21%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On the clinical benefit of on-scalp MEG: A modeling study of on-scalp MEG epileptic activity source estimation ability
Karin Westin, Sándor Beniczky, … Daniel Lundqvist·bioRxiv·Jan 28, 2022
- Towards the automated detection of interictal epileptiform discharges with magnetoencephalography
Raquel Fernández-Martín, Odile Feys, … Vincent Wens·Journal of Neuroscience MethodsPeer-reviewed·Dec 25, 2023
- On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG
Lau M. Andersen, Christoph Pfeiffer, … Daniel Lundqvist·NeuroImagePeer-reviewed·Jul 10, 2020
- Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG
Christoph Pfeiffer, Silvia Ruffieux, … Justin F. Schneiderman·NeuroImagePeer-reviewed·Feb 28, 2020
- Beamforming seizures from the temporal lobe
Luís Garcia Dominguez, Apameh Tarazi, … Richard A Wennberg·bioRxiv·Nov 19, 2021
- Imaging the Extent and Location of Spatiotemporally Distributed Epileptiform Sources from MEG Measurements