NeuroImageNeurosciencePeer-reviewed journal article
On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG
Lau M. AnderseniD, Christoph PfeifferiD, Silvia RuffieuxiD, Bushra RiaziD, Dag WinkleriD, Justin F. SchneidermaniD, Daniel LundqvistiD
Abstract
Magnetoencephalography (MEG) has a unique capacity to resolve the spatio-temporal development of brain activity from non-invasive measurements. Conventional MEG, however, relies on sensors that sample from a distance (20-40 mm) to the head due to thermal insulation requirements (the MEG sensors function at 4 K in a helmet). A gain in signal strength and spatial resolution may be achieved if sensors are moved closer to the head. Here, we report a study comparing measurements from a seven-channel on-scalp SQUID MEG system to those from a conventional (in-helmet) SQUID MEG system.\n\nWe compared spatio-temporal resolution between on-scalp and conventional MEG by comparing the discrimination accuracy for neural activity patterns resulting from stimulating five different phalanges of the right hand. Because of proximity and sensor density differences between on-scalp and conventional MEG, we hypothesized that on-scalp MEG would allow for a more high-resolved assessment of these activity patterns, and therefore also a better classification performance in discriminating between neural activations from the different phalanges.\n\nWe observed that on-scalp MEG provided better classification performance during an early post-stimulus period (15-30 ms). This corresponded to electroencephalographic (EEG) response components N16 and P23, and was an unexpected observation as these components are usually not observed in conventional MEG. They indicate that on-scalp MEG opens up for a richer registration of the cortical signal, allowing for sensitivity to what are potentially sources in the thalamo-cortical radiation and to quasi-radial sources.\n\nWe had originally expected that on-scalp MEG would provide better classification accuracy based on activity in proximity to the P60m component compared to conventional MEG. This component indeed allowed for the best classification performance for both MEG systems (60-75%, chance 50%). However, we did not find that on-scalp MEG allowed for better classification than conventional MEG at this latency. We believe this may be due to the limited sensor coverage in the recording, in combination with our strategy for positioning the on-scalp MEG sensors. We discuss how sensor density and coverage as well as between-phalange source field dissimilarities may influence our hypothesis testing, which we believe to be useful for future benchmarking measurements.
- Citations
- 29
- FWCI
- 1.88
- Field percentile
- top 16%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Requirements for coregistration accuracy in on-scalp MEG
Rasmus Zetter, Joonas Iivanainen, … Lauri T. Parkkonen·Brain TopographyPeer-reviewed·Jun 22, 2018
- Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG
Mainak Jas, Teppei Matsubara, … Seppo P. Ahlfors·bioRxiv·Aug 21, 2026
- Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG
Christoph Pfeiffer, Silvia Ruffieux, … Justin F. Schneiderman·NeuroImagePeer-reviewed·Feb 28, 2020
- Potential of on-scalp MEG: Robust detection of human visual gamma-band responses
Joonas Iivanainen, Rasmus Zetter, Lauri T. Parkkonen·Human Brain MappingPeer-reviewed·Oct 1, 2019
- A 7-channel high-Tc SQUID-based on-scalp MEG system
Christoph Pfeiffer, Silvia Ruffieux, … Justin F. Schneiderman·bioRxiv·Jan 31, 2019