NeuroImageNeurosciencePeer-reviewed journal article
Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG
Christoph PfeifferiD, Silvia RuffieuxiD, Lau M. AnderseniD, Alexei Kalabukhov, Dag WinkleriD, Robert OostenveldiD, Daniel LundqvistiD, Justin F. SchneidermaniD
Abstract
Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individuals head. In conventional MEG, positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subjects head shape and size. The positions and orientations of on-scalp sensors must therefore be measured at every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around.\n\nIn this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subjects head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-Tc SQUIDs). The method provides accurate estimates of individual sensor positions and orientations with short averaging time ([≤] 2 mm and < 3 degrees, respectively, with 1-second averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the localization accuracy (< 1 mm and < 2.5 degrees, respectively, with 1-second coil recordings).\n\nWe demonstrate source localization of on-scalp recorded somatosensory evoked activity based on co-registration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 5.3 mm) with those based on a commercial, whole-head MEG system.
- Citations
- 27
- FWCI
- 1.61
- Field percentile
- top 19%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Requirements for coregistration accuracy in on-scalp MEG
Rasmus Zetter, Joonas Iivanainen, … Lauri T. Parkkonen·Brain TopographyPeer-reviewed·Jun 22, 2018
- Optical Co-registration of MRI and On-scalp MEG
Rasmus Zetter, Joonas Iivanainen, Lauri T. Parkkonen·Scientific ReportsPeer-reviewed·Apr 2, 2019
- On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG
Lau M. Andersen, Christoph Pfeiffer, … Daniel Lundqvist·NeuroImagePeer-reviewed·Jul 10, 2020
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements
Karin Westin, Christoph Pfeiffer, … Daniel Lundqvist·Clinical NeurophysiologyPeer-reviewed·May 10, 2020
- A 7-channel high-Tc SQUID-based on-scalp MEG system
Christoph Pfeiffer, Silvia Ruffieux, … Justin F. Schneiderman·bioRxiv·Jan 31, 2019