Magnetic Resonance in MedicineNeurosciencePeer-reviewed journal article
Phase Unwrapping with a Rapid Opensource Minimum Spanning TreE AlgOrithm (ROMEO)
Barbara DymerskaiD, Korbinian EcksteiniD, Beata BachrátáiD, Bernard M. SiowiD, Siegfried TrattnigiD, Karin ShmueliiD, Simon RobinsoniD
Abstract
PurposeTo develop a rapid and accurate MRI phase unwrapping technique for challenging phase topographies encountered at high magnetic fields, around metal implants or post-operative cavities, that is sufficiently fast to be applied to large group studies including Quantitative Susceptibility Mapping and functional MRI (with phase-based distortion correction). MethodsThe proposed path-following phase unwrapping algorithm, ROMEO, estimates the coherence of the signal both in space - using MRI magnitude and phase information - and over time, assuming approximately linear temporal phase evolution. This information is combined to form a quality map that guides the unwrapping along a three-dimensional path through the object using a computationally efficient minimum spanning tree algorithm. ROMEO was tested against the two most commonly used exact phase unwrapping methods: PRELUDE and BEST PATH in simulated topographies and at several field strengths: in 3 T and 7 T in vivo human head images and 9.4 T ex vivo rat head images. ResultsROMEO was more reliable than PRELUDE and BEST PATH, yielding unwrapping results with excellent temporal stability for multi-echo or multi-time-point data. ROMEO does not require image masking and delivers results within seconds even in large, highly wrapped multi-echo datasets (e.g. 9 seconds for a 7 T head dataset with 31 echoes and a 208 x 208 x 96 matrix size). ConclusionOverall, ROMEO was both faster and more accurate than PRELUDE and BEST PATH delivering exact results within seconds, which is well below typical image acquisition times, enabling potential on-console application.
- organism: human
- organism: rat
- assay: multiome
- research focus: benchmarking
- approach: statistical model
- approach: experimental assay
- Citations
- 125
- FWCI
- 4.62
- Field percentile
- top 3%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Validation of Data Acquisition and Phase Estimation for Quantitative Susceptibility Mapping with a Rotating-Tube Phantom
K. E. Keenan, B. P. Berman, … J. Dagher·bioRxiv·Jun 29, 2021
- FONDUE: Robust resolution-invariant denoising of MR Images using Nested UNets
Walter Adame‐Gonzalez, Aliza Brzezinski-Rittner, … Mahsa Dadar·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Multi-echo Quantitative Susceptibility Mapping: How to Combine Echoes for Accuracy and Precision at 3 T
Emma Biondetti, Anita Karsa, … Karin Shmueli·Magnetic Resonance in MedicinePeer-reviewed·Jun 29, 2022
- QSM Reconstruction Challenge 2.0: a realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures
José P. Marques, Jakob Meineke, … Ferdinand Schweser·Magnetic Resonance in MedicinePeer-reviewed·Feb 26, 2021
- Improved motion correction of submillimetre 7T fMRI time series with boundary-based registration (BBR)
Pei Huang, J. D. Carlin, … M. M. Correia·bioRxiv·Aug 28, 2019
- Myelin Imaging Using 3D Dual-echo Ultra-short Echo Time MRI with Rosette k-Space Pattern
Xin Shen, Ali Çağlar Özen, … Uzay E. Emir·bioRxiv·Sep 18, 2021