Myelin Imaging Using 3D Dual-echo Ultra-short Echo Time MRI with Rosette k-Space Pattern
Xin SheniD, Ali Çağlar ÖzeniD, Antonia Sunjar, Serhat İlbeyiD, Riyi ShiiD, Mark ChiewiD, Uzay E. EmiriD
Abstract
PurposeThis study aimed to develop a new 3D dual-echo rosette k-space trajectory, specifically for ultra-short echo time (UTE) magnetic resonance imaging (MRI) applications. The direct imaging of the myelin bilayer, which has ultra-short transverse relaxation time (uT2), was acquired to test the performance of the proposed UTE sequence. Theory and MethodsThe rosette trajectory was developed based on rotations of a petal-like pattern in the kx-ky plane, with oscillated extensions in kz-direction for 3D coverage. Five healthy volunteers were recruited and underwent ten dual-echo 3D rosette UTE scans with various echo times (TEs). Dual-exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long T2 value. ResultsThe reconstructed images signal contrast between whiate matter (WM) and grey matter (GM) increased with longer TEs. The WM regions had higher uT2 fraction values than GM (10.9%{+/-}1.9% vs. 5.7%{+/-}2.4%). The uT2 value was approximately 0.15 milliseconds in WM. ConclusionThe higher uT2 fraction value in WM compared to GM demonstrated the ability of the proposed sequence to capture rapidly decaying signals.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 2
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High-Resolution 3D Ultra-Short Echo Time MRI with Rosette k-Space Pattern for Brain Iron Content Mapping
Xin Shen, Ali Çağlar Özen, … Uzay E. Emir·Journal of Trace Elements in Medicine and BiologyPeer-reviewed·May 1, 2023
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI
F. Wang, Z. Dong, … K. Setsompop·bioRxiv·May 6, 2021
- Ultrashort-T2* mapping at 7 tesla using an optimized pointwise encoding time reduction with radial acquisition (PETRA) sequence at standard and extended echo times
Carly A. Lockard, Bruce M. Damon, Haçène Serrai·PLoS ONEPeer-reviewed·Apr 17, 2025
- Multi-site Ultrashort Echo Time 3D Phosphorous MRSI repeatability using novel Rosette Trajectory (PETALUTE)
Şeyma Alçiçek, Alexander R. Craven, … Uzay E. Emir·bioRxiv·Feb 7, 2024
- T1-weighted fMRI in mouse visual cortex using an Iron Oxide Nanoparticle contrast agent and Ultrashort Echo Time (UTE) imaging at 9.4 T
Naman Vijaykumar Jain, Saskia Bollmann, … Markus Barth·bioRxiv·Mar 17, 2025
- Time-division multiplexing (TDM) sequence removes bias in T2 estimation and relaxation-diffusion measurements
Qiang Liu, Borjan A. Gagoski, … Lipeng Ning·Magnetic Resonance in MedicinePeer-reviewed·Aug 13, 2024