Brain stimulationNeurosciencePeer-reviewed journal article
TMS with fast and accurate electronic control: measuring the orientation sensitivity of corticomotor pathways
Victor Hugo SouzaiD, Jaakko O. NiemineniD, Sergei TuginiD, Lari M. KoponeniD, Oswaldo BaffaiD, Risto Juhani IlmoniemiiD
Abstract
BackgroundTranscranial magnetic stimulation (TMS) coils allow only a slow, mechanical adjustment of the stimulating electric field (E-field) orientation in the cerebral tissue. Fast E-field control is needed to synchronize the stimulation with the ongoing brain activity. Also, empirical models that fully describe the relationship between evoked responses and the stimulus orientation and intensity are still missing. ObjectiveWe aimed to (1) develop a TMS transducer for manipulating the E-field orientation electronically with high accuracy at the neuronally meaningful millisecond-level time scale and (2) devise and validate a physiologically based model describing the orientation selectivity of neuronal excitability. MethodsWe designed and manufactured a two-coil TMS transducer. The coil windings were computed with a minimum-energy optimization procedure, and the transducer was controlled with our custom-made electronics. The electronic E-field control was verified with a TMS characterizer. The motor evoked potential amplitude and latency of a hand muscle were mapped in 3{degrees} steps of the stimulus orientation in 16 healthy subjects for three stimulation intensities. We fitted a logistic model to the motor response amplitude. ResultsThe two-coil TMS transducer allows one to manipulate the pulse orientation accurately without manual coil movement. The motor response amplitude followed a logistic function of the stimulus orientation; this dependency was strongly affected by the stimulus intensity. ConclusionThe developed electronic control of the E-field orientation allows exploring new stimulation paradigms and probing neuronal mechanisms. The presented model helps to disentangle the neuronal mechanisms of brain function and guide future non-invasive stimulation protocols.
- Citations
- 54
- FWCI
- 3.87
- Field percentile
- top 5%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Effects of Electric Field Direction on TMS-based Motor Cortex Mapping
Ying Jing, Ole Numssen, … Konstantin Weise·Imaging NeurosciencePeer-reviewed·Jan 1, 2026
- Multi-locus transcranial magnetic stimulation system for electronically targeted brain stimulation
Jaakko O. Nieminen, Heikki Sinisalo, … Risto Juhani Ilmoniemi·Brain stimulationPeer-reviewed·Nov 21, 2021
- Directional Sensitivity of Cortical Neurons Towards TMS Induced Electric Fields
Konstantin Weise, Torge Worbs, … Thomas R. Knösche·Imaging NeurosciencePeer-reviewed·Nov 13, 2023
- The dependency of TMS-evoked potentials on electric-field orientation in the cortex
Ida Granö, Tuomas P. Mutanen, … Pantelis Lioumis·Brain stimulationPeer-reviewed·Apr 29, 2025
- Validating models of TMS effects with concurrent TMS/fMRI
Petar I. Petrov, Jord J. T. Vink, … Sebastiaan F.W. Neggers·bioRxiv·Jul 5, 2023
- Simulation of transcranial magnetic stimulation in head model with morphologically-realistic cortical neurons
A. Aberra, B. Wang, … A. V. Peterchev·bioRxiv·Dec 26, 2018