Photon-counting cine-cardiac CT in the mouse
Abstract
The maturation of photon-counting detector (PCD) technology promises to enhance routine CT imaging applications with high-fidelity spectral information. In this paper, we demonstrate the power of this synergy and our complementary reconstruction techniques, performing 4D, cardiac PCD-CT data acquisition and reconstruction in a mouse model of atherosclerosis, including calcified plaque. Specifically, in vivo cardiac micro-CT scans were performed in four ApoE knockout mice, following their development of calcified plaques. The scans were performed with a prototype PCD (DECTRIS, Ltd.) with 4 energy thresholds. Projection sampling was performed with 10 ms temporal resolution, allowing the reconstruction of 10 cardiac phases at each of 4 energies (40, 3D volumes per mouse scan). Reconstruction was performed iteratively using the split Bregman method with constraints on spectral rank and spatio-temporal gradient sparsity. The reconstructed images represent the first in vivo, 4D PCD-CT data in a mouse model of atherosclerosis. Robust regularization during iterative reconstruction yields high-fidelity results: an 8-fold reduction in noise standard deviation for the highest energy threshold (relative to algebraic reconstruction), while absolute spectral bias measurements remain below 13 Hounsfield units across all energy thresholds and scans. Qualitatively, image domain material decomposition results show clear separation of iodinated contrast and soft tissue from calcified plaque in the in vivo data. Quantitatively, spatial, spectral, and temporal fidelity are verified through a water phantom scan and a realistic MOBY phantom simulation experiment: spatial resolution is robustly preserved by iterative reconstruction (10% MTF: 2.8-3.0 lp/mm), left-ventricle, cardiac functional metrics can be measured from iodine map segmentations with [~]1% error, and small calcifications (615 m) can be detected during slow moving phases of the cardiac cycle. Given these preliminary results, we believe that PCD technology will enhance dynamic CT imaging applications with high-fidelity spectral and material information.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Phosphotungstic acid (PTA) preferentially binds to collagen-rich regions of porcine carotid arteries and human atherosclerotic plaques using 3D micro-computed tomography (CE-μCT)
A. Hanly, R. D. Johnston, … C. Lally·bioRxiv·Jul 14, 2022
- Micro-CT: A reversible contrast-based protocol for non-destructive imaging of cardiac morphology in an avian model.
Joshua Durrans, Nicola Aberdein, … Mari Herigstad·bioRxiv·Jul 15, 2026
- Multidimensional Analysis of the Adult Human Heart in Health and Disease using Hierarchical Phase-Contrast Tomography (HiP-CT)
J. Brunet, A. C. Cook, … P. D. Lee·bioRxiv·Oct 9, 2023
- High resolution micro-CT imaging in mice stroke models: from 3D detailed infarct characterization to automatic area segmentation
Raquel Pinto, Jan Matula, … João R. Gomes·bioRxiv·Feb 2, 2022
- Physiological motion of the carotid atherosclerotic plaque quantified using ultrasound B-Mode image analysis
Baris Kanber, Timothy C. Hartshorne, … Kumar V. Ramnarine·bioRxiv·Feb 5, 2018
- Quantitative Molecular Imaging of Breast Microcalcification Composition using Photon-Counting Spectral Computed Tomography
T. E. Curtis, R. K. Roeder·bioRxiv·Sep 16, 2020