Reversible edema following electric drilling of macaque craniotomy
Rober BoshraiD, Manoj Kumar EradathiD, Kacie DoughertyiD, Bichan Wu, Britney M. MoreaiD, Mark A. Pinsk, Sabine KästneriD
Abstract
In-vivo electrophysiology requires direct access to brain tissue, necessitating the development and refinement of surgical procedures and techniques that promote the health and well-being of the animal subjects. Here, we report a series of findings noted on structural magnetic resonance imaging (MRI) scans in monkeys with MRI-compatible implants following small craniotomies that provide access for intracranial electrophysiology. We found distinct brain regions exhibiting hyperintensities in T2-weighted scans that were prominent underneath the sites at which craniotomies had been performed. We interpreted these hyperintensities as edema of the neural tissue and found that they were predominantly present following electric drilling, but not when manual, hand-operated drills were used. Further, the anomalies subsided within 2-3 weeks following surgery. Our report highlights the utility of MRI-compatible implants that promote clinical examination of the animals brain, sometimes revealing findings that may go unnoticed when incompatible implants are used. We show replicable differences in outcome when using electric vs. mechanical devices, both ubiquitous in the field. If electric drills are used, our report cautions electrophysiological recordings from tissue directly underneath the craniotomy for the first 2-3 weeks following the procedure due to putative edema.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- An Open-Source Rodent Chronic EEG Array System with High Density MXene-Based Skull Surface Electrodes
Li Ding, Aashvi Patel, … Martin J. Gallagher·bioRxiv·Dec 28, 2022
- A minimally invasive EEG recording method in mice using thin needle electrodes
Bende Zou, Xinmin Xie, Ludmila Gerashchenko·bioRxiv·Apr 3, 2026
- Electrical Fields Induced Inside the Rat Brain with Skin, Skull, and Dural Placements of the Current Injection Electrode
Ahmet S. Asan, Sinan Gok, Mesut Şahin·PLoS ONEPeer-reviewed·Jan 10, 2019
- In Vivo Localization of Deep Brain Implants in Mice
Bálint Király, Diána Balázsfi, … Balázs Hangya·bioRxiv·Mar 28, 2020
- Repeatable, low-drift recordings in behaving non-human primates using flexible microelectrodes
Daniel P. Woods, Grace Adams, … Daniel L. Gonzales·Nature CommunicationsPeer-reviewed·Sep 9, 2026
- The Surgical Method of Craniectomy Differentially Affects Acute Seizures, Brain Deformation and Behavior in a TBI Animal Model
Cesar Santana‐Gomez, Gregory Smith, … Richard J. Staba·bioRxiv·Jun 28, 2024