Ultrasound in Medicine & BiologyNeurosciencePeer-reviewed journal article
Acoustic Coupling for Double-Blind Human Low-Intensity Focused Ultrasound Neuromodulation
Aditya KapooriD, Andrew StrohmaniD, Yunruo Ni, Gabriel IsaaciD, Jason L. RaymondiD, Wynn LegoniD
Abstract
ObjectiveLow-intensity focused ultrasound (LIFU) is a non-invasive neuromodulation technique with the potential for precise targeting of small and deep human brain circuitry. To ensure rigorous and reproducible effects, it is necessary to implement double-blinding to mitigate potential experimental biases. This study innovates on previous ultrasound coupling methods by embedding a 3D-printed thermoplastic disc in a high-density gel-polymer matrix to create identical gel-plastic coupling devices that either transmit (verum) or block (sham) ultrasound. MethodsWe evaluated varying thicknesses (1.5 mm, 2,0 mm, 2.5 mm) and infill densities (25%, 50%, 75%, and 100%) of Acrylonitrile Butadiene Styrene (ABS) for insertion loss and effects on beam characteristics across relevant human neuromodulation frequencies from 0.2 - 1 MHz. ResultsABS at 1.5 mm thickness and 50 % infill had the lowest insertion loss at 0.50 MHz of 0.9 {+/-} 0.04 dB demonstrating acoustic transparency suitable for a verum device. For the sham device, we introduced an internal air gap that produced 31 dB insertion loss at 0.50 MHz. The verum device demonstrated minimal effects on the beam shape with a radial peak shift of 0.3 {+/-} 0.2 mm and an average axial shift of 0.5 mm. DiscussionThis novel gel-plastic coupling device can be tailored to most LIFU transducer shapes and is designed to support double-blind protocols by maintaining visual and tactile indistinguishability while controlling transmitted energy. This method provides a cost-effective and easily implementable solution for double-blinding in human LIFU studies to improve the reliability and rigor of experimental outcomes.
- Citations
- 3
- FWCI
- 5.14
- Field percentile
- top 6%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Development of Visually Indistinguishable Acoustic Coupling Pads for Double-Blind Focused Ultrasound Neuromodulation Studies
Samantha Schafer, Norman M. Spivak, … Mark Evan Schafer·Ultrasound in Medicine & BiologyPeer-reviewed·Aug 13, 2026
- Examination of low-intensity focused ultrasound parameters for human neuromodulation
Areej N. Ennasr, Gabriel Isaac, … Wynn Legon·bioRxiv·Sep 23, 2024
- Mechanistic modeling suggests that low-intensity focused ultrasound can selectively recruit myelinated or unmyelinated nerve fibers
Théo Lemaire, Elena Vicari, … Silvestro Micera·iSciencePeer-reviewed·Sep 1, 2021
- Bayesian-enhanced closed-loop optimization of ultrasound protocols for targeted and precise neuromodulation
Andrea Boscutti, Valeria Grasso, Tommaso Di Ianni·bioRxiv·Jun 18, 2026
- Bioadhesive Hydrogel-Coupled and Miniaturized Ultrasound Transducer System for Long-Term, Wearable Neuromodulation
Kai Wing Kevin Tang, Jinmo Jeong, … Huiliang Wang·Nature CommunicationsPeer-reviewed·May 28, 2025
- Low-intensity focused ultrasound pulsation along the anterior-posterior thalamic axis differentially modulates the latency of reporting conscious visual experience
Hyunwoo Jang, Jiyang Liu, … Zirui Huang·bioRxiv·Aug 25, 2026