PLoS ONENeurosciencePeer-reviewed journal article
A multifaceted suite of metrics for comparative myoelectric prosthesis controller research
Heather E. WilliamsiD, Ahmed W. ShehataiD, Kodi Y. Cheng, Jacqueline S. HebertiD, Patrick M. PilarskiiD
Abstract
Upper limb robotic (myoelectric) prostheses are technologically advanced, but challenging to use. In response, substantial research is being done to develop user-specific prosthesis controllers that can predict a persons intended movements. Most studies that test and compare new controllers rely on simple assessment measures such as task scores (e.g., number of objects moved across a barrier) or duration-based measures (e.g., overall task completion time). These assessment measures, however, fail to capture valuable details about: the quality of device arm movements; whether these movements match users intentions; the timing of specific wrist and hand control functions; and users opinions regarding overall device reliability and controller training requirements. In this work, we present a comprehensive and novel suite of myoelectric prosthesis control evaluation metrics that better facilitates analysis of device movement details--spanning measures of task performance, control characteristics, and user experience. As a case example of their use and research viability, we applied these metrics in real-time control experimentation. Here, eight participants without upper limb impairment compared device control offered by a deep learning-based controller (recurrent convolutional neural network-based classification with transfer learning, or RCNN-TL) to that of a commonly used controller (linear discriminant analysis, or LDA). The participants wore a simulated prosthesis and performed complex functional tasks across multiple limb positions. Analysis resulting from our suite of metrics identified 16 instances of a user-facing problem known as the "limb position effect". We determined that RCNN-TL performed the same as or significantly better than LDA in four such problem instances. We also confirmed that transfer learning can minimize user training burden. Overall, this study contributes a multifaceted new suite of control evaluation metrics, along with a guide to their application, for use in research and testing of myoelectric controllers today, and potentially for use in broader rehabilitation technologies of the future.
- Citations
- 6
- FWCI
- 0.66
- Field percentile
- top 42%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Myoelectric Prosthesis Control using Recurrent Convolutional Neural Network Regression Mitigates the Limb Position Effect
H. E. Williams, A. W. Shehata, … P. M. Pilarski·bioRxiv·Feb 5, 2024
- Evaluating Internal Model Strength and Performance of Myoelectric Prosthesis Control Strategies
A. W. Shehata, E. J. Scheme, J. W. Sensinger·bioRxiv·Feb 3, 2018
- Discrete action control for prosthetic digits
A. Krasoulis, K. Nazarpour·bioRxiv·Mar 25, 2020
- Successful transfer of myoelectric skill from virtual interface to prosthesis control
Sigrid S. G. Dupan, Simon A. Stuttaford, Dyson M·Journal of Neural EngineeringPeer-reviewed·Dec 1, 2025
- Limb Position Effect in Myoelectric Control: Strategies for Optimisation and Standardisation
Trevor Overton, Zubaidah Al-Mashhadani, … Mohsen Rakhshan·Journal of Neural EngineeringPeer-reviewed·Mar 19, 2026
- Model-based control of individual finger movements for prosthetic hand function
D. Blana, A. J. van den Bogert, … E. K. Chadwick·bioRxiv·May 7, 2019