bioRxivBioengineering
Evaluating Internal Model Strength and Performance of Myoelectric Prosthesis Control Strategies
Abstract
Ongoing developments in myoelectric prosthesis control have provided prosthesis users with an assortment of control strategies that vary in reliability and performance. Many studies have focused on improving performance by providing feedback to the user, but have overlooked the effect of this feedback on internal model development, which is key to improving long-term performance. In this work, the strength of internal models developed for two commonly used myoelectric control strategies: raw control with raw feedback (using a regression-based approach), and filtered control with filtered feedback (using a classifier-based approach), were evaluated using two psychometric measures: trial-by-trial adaptation and just-noticeable-difference. The performance of both strategies was also evaluated using a Schmidts style target acquisition task. Results obtained from 24 able-bodied subjects showed that although filtered control with filtered feedback had better short-term performance in path efficiency (p < 0.05), raw control with raw feedback resulted in stronger internal model development (p < 0.05), which may lead to better long-term performance. Despite inherent noise in the control signals of the regression controller, these findings suggest that rich feedback associated with regression control may be used to improve human understanding of the myoelectric control system.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Audible Feedback Improves Internal Model Strength and Performance of Myoelectric Prosthesis Control
A. W. Shehata, E. J. Scheme, J. W. Sensinger·bioRxiv·May 21, 2018
- Successful transfer of myoelectric skill from virtual interface to prosthesis control
Sigrid S. G. Dupan, Simon A. Stuttaford, Dyson M·Journal of Neural EngineeringPeer-reviewed·Dec 1, 2025
- A multifaceted suite of metrics for comparative myoelectric prosthesis controller research
Heather E. Williams, Ahmed W. Shehata, … Patrick M. Pilarski·PLoS ONEPeer-reviewed·May 13, 2024
- Artificial Joint Speed Feedback for Myoelectric Prosthesis Control
Eric J. Earley, Reva E. Johnson, … Levi J. Hargrove·Scientific ReportsPeer-reviewed·Mar 4, 2021
- Effect of user adaptation on prosthetic finger control with an intuitive myoelectric decoder
A. Krasoulis, S. Vijayakumar, K. Nazarpour·bioRxiv·Aug 9, 2019
- Measuring and monitoring skill learning in closed-loop myoelectric hand prostheses using speed-accuracy tradeoffs
P. Mamidanna, S. Gholinezhad, … S. Dosen·bioRxiv·Aug 10, 2023