Bivariate confidence probability plots as a method to test the accuracy and variability of microbiological measures
Abstract
IntroductionIn an interlaboratory calibration analysis to validate a methodology that will be proposed as a European standard for domestic laundry disinfection, tests were carried out to detect if there are different behaviors in the measurements regarding accuracies and variabilities. Interlaboratory tests using different doses of disinfectant and microorganisms were carried out. ISO 5725-2 and ISO 13528 form the basis of validations of quantitative methods, providing validation specifications for interlaboratory studies. However, a need for a simple graphical method to detect interlaboratory differences in accuracy and variability was observed. ObjectivesThe general goal of this work is to present a new exploratory methodology, graphical and easy to interpret, that can determine the accuracy and variability (precision) of a variable, and compare it to the methodology applied in ISO 5725-2 and ISO 13528. MethodsWe used confidence probability plots of the multivariate Students t-distribution to observe the accuracy and variability of microbiological measures carried out by different laboratories during a ring trial exercise. A function in R was built for this purpose: Miriam.analysis.ellipse(Y, factor_a, eel.plot = " t-Student"). The different observations of accuracy and variability are represented in the ellipses. If any of the points are outside the ellipse with 95% confidence, we can assume a deviation in accuracy and / or variability. ResultsTwo examples are provided with real microbiological data (logarithmic unit reductions (LR) for Pseudomonas aeruginosa, Escherichia coli, Staphilococcus aureus, Enterococcus hirae, Candida albicans and microbial counts in water (WW)). The proposed new method allowed us to detect possible deviations in the WWMEA variable and we believe it has future application for the rapid control of microbiological measures.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Iterative Cochran's C test as a multivariate method to detect higher than expected variability: a microbiological inter-laboratory ring trial as a case-study
A. Monleon-Getino, AC Marca Home Care·bioRxiv·Nov 19, 2020
- Statistical calibration of microbial suspensions in carrier controls during a textile disinfection ring trial
A. Monleon-Getino, AC Marca Home Care·bioRxiv·Nov 19, 2020
- Measurement Quality Metrics to Improve Absolute Microbial Cell Counting
Kirsten H. Parratt, David C. Newton, … Nancy J. Lin·Frontiers in MicrobiologyPeer-reviewed·Aug 18, 2025
- Reproducibility problem with a proposed standard method to measure disinfection efficacy
J. Hilgren, M. Srikanth, … The Efficacy Working Group·bioRxiv·Mar 15, 2022
- Assessing measurement uncertainty at laboratory network scale and its impact on diagnostic performance in the absence of a gold standard: application to ELISA tests for Coxiella burnetii in ruminants
Laureline Rivière, Marie Laure Delignette‐Muller, … Élodie Rousset·bioRxiv·Sep 11, 2026
- An Assessment of Skin Lesion Measurement Techniques for Use in Clinical Trials of Acute Bacterial Skin and Skin Structure Infections