Multi-site Ultrashort Echo Time 3D Phosphorous MRSI repeatability using novel Rosette Trajectory (PETALUTE)
Şeyma AlçiçekiD, Alexander R. CraveniD, Xin SheniD, Mark ChiewiD, Ali Çağlar ÖzeniD, Stephen J. SawiakiD, Ulrich PilatusiD, Uzay E. EmiriD
Abstract
PurposeThis study aims 1) to implement an operator-independent acquisition, reconstruction, and processing pipeline using a novel rosette k-space pattern for UTE 31P 3D MRSI and 2) to evaluate the clinical applicability and replicability at different experimental setups. MethodsA multicenter repeatability study was conducted for the novel UTE 31P 3D Rosette MRSI at three institutions with different experimental setups. Non-localized 31P MRSI data of 5 healthy subjects at each site were acquired with an acquisition delay of 65 s and a final resolution of 10 x 10 x 10 mm3 in 9 min. Spectra were quantified using the LCModel package. The potential acceleration was achieved using compressed sensing on retrospectively undersampled data. Reproducibility at each site was evaluated using the inter-subject coefficient of variance. ResultsThis novel acquisition and advanced processing techniques yielded high-quality spectra and enabled the detection of the critical brain metabolites at three different sites with different hardware specifications. In vivo, feasibility with an acceleration factor of 4 in 6.75 min resulted in a mean Cramer-Rao lower bounds below 20% for PCr, ATPs, PME, and the mean CoV of ATP/PCr resulted in below %20. ConclusionWe demonstrated that UTE 31P 3D Rosette MRSI acquisition, combined with compressed sensing and LCModel analysis, allows patient-friendly, operator-independent, high-resolution 31P MRSI to be acquired at clinical setups.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)
W. T. Clarke, L. Hingerl, … C. T. Rodgers·bioRxiv·Dec 10, 2021
- Whole-Brain High-Resolution Metabolite Mapping with 3D Compressed-Sensing-SENSE-LowRank 1H FID-MRSI
Antoine Klauser, Paul Klauser, … François Lazeyras·NMR in BiomedicinePeer-reviewed·Oct 1, 2021
- Achieving High-Resolution Whole-Brain Slab 1H-MRSI with Compressed-Sensing and Low-Rank Reconstruction at 7 Tesla
Antoine Klauser, Bernhard Strasser, … Ovidiu C. Andronesi·Journal of Magnetic ResonancePeer-reviewed·Aug 11, 2021
- Time-efficient relaxation measurements by 31P MR fingerprinting in human brain at 7T
S.-I. Lim, M. S. Widmaier, … L. Xin·bioRxiv·May 23, 2022
- Density-Weighted Concentric Ring Trajectory using simultaneous multi-band acceleration: 3D Metabolite-cycled Magnetic Resonance Spectroscopy Imaging at 3 T
Pingyu Xia, Mark Chiew, … Uzay E. Emir·bioRxiv·May 5, 2019
- Myelin Imaging Using 3D Dual-echo Ultra-short Echo Time MRI with Rosette k-Space Pattern
Xin Shen, Ali Çağlar Özen, … Uzay E. Emir·bioRxiv·Sep 18, 2021