Wide-pulse electrical stimulation of the quadriceps femoris allows greater maximal evocable torque than conventional stimulation
L. Espeit, T. Lapole, G. Y. Millet, V. Rozand, N. A. Maffiuletti
Abstract
PurposeThe effectiveness of a neuromuscular electrical stimulation (NMES) program has been shown to be proportional to the maximal evocable torque (MET), which is potentially influenced by pulse characteristics such as duration and frequency. The aim of this study was to compare MET between conventional and wide-pulse NMES at two different frequencies. MethodsMET - expressed as a percentage of maximal voluntary contraction (MVC) torque - and maximal tolerable current intensity (MTCI) were quantified on 71 healthy subjects. The right quadriceps femoris muscle was stimulated with three NMES protocols using different pulse duration/frequency combinations: conventional NMES (0.2 ms/50 Hz; CONV), wide-pulse NMES at 50 Hz (1 ms/50 Hz; WP50) and wide-pulse NMES at 100 Hz (1 ms/100 Hz; WP100). The proportion of subjects reaching the maximal stimulator output (100 mA; MSO) before attaining MTCI was also quantified for each NMES protocol. ResultsThe proportion of subjects attaining MSO was higher for CONV than WP50 and WP100 (30%, 3% and 4%, respectively; p < 0.001). In subjects who did not attain MSO in any protocol, MET was higher for both WP50 and WP100 than for CONV (45% vs 43% vs 39% MVC; p < 0.001). MTCI was lower for both WP50 and WP100 than for CONV (45, 42, and 77 mA, respectively; p < 0.001) and was also lower for WP100 than for WP50. ConclusionWhen compared to conventional NMES, wide-pulse protocols resulted in greater MET, lower MTCI and consequently in a lower proportion of subjects attaining MSO. Overall, this may lead to better NMES training/rehabilitation effectiveness and less practical issues associated with MSO limitations.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Intensity and dose of neuromuscular electrical stimulation influence sensorimotor cortical excitability
Ainhoa Insausti-Delgado, Eduardo López‐Larraz, … Ander Ramos‐Murguialday·Frontiers in NeurosciencePeer-reviewed·Jan 15, 2021
- Repeated Neuromuscular Electrical Stimulation Protocol Disrupts Muscle-to-Brain Signaling in Rats
Julien Wirtz, Yuan Wang, … Philippe E Garnier·bioRxiv·Oct 14, 2026
- Pulse-Width Modulation-based TMS mimics effects of conventional TMS on human primary motor cortex
Majid Memarian Sorkhabi, Karen Wendt, … Timothy Denison·bioRxiv·Nov 24, 2021
- Effects of neuromuscular priming with spinal cord transcutaneous stimulation on lower limb motor performance in young active males
Simone Zaccaron, Lara Mari, … Enrico Rejc·bioRxiv·Mar 9, 2025
- Custom-Built Electrodes Perform Comparably to a Discontinued Commercial Electrode for Neuromuscular Electrical Stimulation in Mice
Bana H. Odeh, Amanda L. Wellman, … Joseph A. Roche·PhysiologyPeer-reviewed·May 1, 2026
- Increasing pulse energy of 5Hz rTMS improves its efficacy in inducing excitatory aftereffects.
Islam Halawa, K Reichert, … Walter Paulus·bioRxiv·Dec 16, 2019