Microneurography as a Minimally Invasive Method to Assess Target Engagement During Neuromodulation
N. Verma, B. Knudsen, A. Gholston, A. Skubal, S. Blanz, M. Settell, J. Frank, J. Trevathan, K. Ludwig
Abstract
ObjectivePeripheral neural signals recorded during neuromodulation therapies provide insights into local neural target engagement and serve as a sensitive biomarker of physiological effect. Although these applications make peripheral recordings important for furthering neuromodulation therapies, the invasive nature of conventional nerve cuffs and longitudinal intrafascicular electrodes (LIFEs) limit their clinical utility. Furthermore, cuff electrodes typically record clear asynchronous neural activity in small animal models but not in large animal models. Microneurography, a minimally invasive technique, is already used routinely in humans to record asynchronous neural activity in the periphery. However, the relative performance of microneurography microelectrodes compared to cuff and LIFE electrodes in measuring neural signals relevant to neuromodulation therapies is not well understood. ApproachTo address this gap, we recorded cervical vagus nerve (cVN) electrically evoked compound action potentials (ECAPs) and spontaneous activity in a human-scaled large animal model - the pig. Additionally, we recorded sensory evoked activity and both invasively and non-invasively evoked CAPs from the great auricular nerve (GAN). In aggregate, this study assesses the potential of microneurography electrodes to measure neural activity during neuromodulation therapies with statistically powered and pre-registered outcomes (https://osf.io/y9k6j). Main resultsThe cuff recorded the largest ECAP signal (p<0.01) and had the lowest noise floor amongst the evaluated electrodes. Despite the lower signal to noise ratio, microneurography electrodes were able to detect the threshold for neural activation with similar sensitivity to cuff and LIFE electrodes once a dose-response curve was constructed. Furthermore, the microneurography electrode was the only electrode to record distinct sensory evoked neural activity (p<0.01). SignificanceThe results show that microneurography electrodes can measure neural signals relevant to neuromodulation therapies. Microneurography could further neuromodulation therapies by providing a real-time biomarker to guide electrode placement and stimulation parameter selection to optimize local neural fiber engagement and study mechanisms of action.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A wrappable microwire electrode for awake, chronic interfacing with small diameter autonomic peripheral nerves
Jessica D. Falcone, Tristan Liu, … Harbaljit S. Sohal·bioRxiv·Sep 8, 2018
- Ultra-flexible and Stretchable Intrafascicular Peripheral Nerve Recording Device with Axon-dimension, Cuff-less Microneedle Electrode Array
Dongxiao Yan, Ahmad A. Jiman, … John P. Seymour·SmallPeer-reviewed·May 1, 2022
- Flat Electrode Contacts for Peripheral Nerve Stimulation
J. Bucksot, A. J. Wells, … S. A. Hays·bioRxiv·Mar 30, 2019
- A mechanically stable neural probe for percutaneous high-resolution, multichannel recordings in peripheral nerves
Sofiia Demchenko, Erkan Yilmaz, … Viviana Rincón Montes·bioRxiv·Apr 14, 2026
- In vivo magnetic recording of neuronal activity
Laure Caruso, Thomas Wunderle, … Myriam Pannetier-Lecoeur·NeuronPeer-reviewed·Aug 30, 2017
- Micromagnetic Stimulation (μMS) Dose-Response of the Rat Sciatic Nerve
R. Saha, Z. Sanger, … J.-P. Wang·bioRxiv·Nov 23, 2022