Method for Modeling Residual Variance in Biomedical Signals Applied to Transcranial Doppler Ultrasonography Waveforms
K. Jalaleddini, S. G. Thorpe, N. Canac, A. Y. Dorn, C. M. Thibeault, S. J. Wilk, R. B. Hamilton
Abstract
Transcranial Doppler (TCD) ultrasonography measures pulsatile cerebral blood flow velocity in the arteries and veins of the head and neck. The velocity pulse waveform morphology has been shown to have physiological and diagnostic significance. However, the measured pulses may exhibit a high degree of variability that deteriorates the estimates of clinical parameters. This study characterizes the TCD residual variance that result in pulse variability.\n\nWe retrospectively utilized the data from 82 subjects. A trained sonographer insonated the middle cerebral arteries using a 2MHz hand-held probe. We implemented a multi-stage algorithm to identify the TCD residuals in each scan: pulses were identified; outlier pulses were flagged and removed; the average pulse waveform was taken as the ensemble average of the accepted pulse waveforms; finally, the resampled average pulse waveforms subtracted from individual pulses were taken as the TCD residuals. For each scan, we reported the signal to noise ratio and parameterized models for residuals: their amplitude structure using probability density function models and their temporal structure using autoregressive models.\n\nThe signal to noise ratio 90% range was [1.7, 18.2] dB. The estimated probability density functions were best characterized by a generalized normal distribution whose beta parameter was smaller than 2 in 93% of scans. The identified frequency structure showed the dynamics were low-pass in nature.\n\nAnalysis of the TCD residuals is useful in the assessment of the signal quality. Moreover, our identified models can also be used to generate synthetic TCD signal that enables future realistic simulation studies.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Objective Assessment of Beat Quality in Transcranial Doppler Measurement of Blood Flow Velocity in Cerebral Arteries
Kian Jalaleddini, Nicolas Canac, … Robert Hamilton·IEEE Transactions on Biomedical EngineeringPeer-reviewed·Jun 17, 2019
- Comparison of Transcranial Doppler Ultrasound with Computational Fluid Dynamics: Responses to Physiological Stimuli
H. T. Caddy, H. J. Thomas, … D. J. Green·bioRxiv·Feb 22, 2022
- Algorithm for Reliable Detection of Beat Onsets in Cerebral Blood Flow Velocity Signals
Nicolas Canac, Mina Ranjbaran, … Robert Hamilton·Frontiers in NeurologyPeer-reviewed·Oct 11, 2019
- Impedance-Derived Heart Rate and Heart Rate Variability from tDCS Output Voltage: Sensorless Physiological Monitoring During Electrical Neuromodulation
Yahia Abdalla, Benjamin Babaev, … Mohamad FallahRad·bioRxiv·Jul 30, 2026
- Analysis of physiological noise in quantitative cardiac magnetic resonance
- Frequency modulated semi-continuous wave Doppler ultrasound: A novel method for the detection of scatterer velocity and range using wearable ultrasound instrumentation
Connor Michael Delaney, Ahmed Bashatah, … Siddhartha Sikdar·bioRxiv·Oct 22, 2026