Affordable and Effective Optokinetic Response Methods to Assess Visual Acuity and Contrast Sensitivity in Larval to Juvenile Zebrafish
Alicia Gómez SáncheziD, Yolanda Álvarez, Basilio ColligrisiD, Breandán N. KennedyiD
Abstract
BackgroundThe optokinetic response (OKR) is an effective behavioural assay to investigate functional vision in zebrafish. The rapid and widespread use of gene editing, drug screening and environmental modulation technologies have resulted in a broader need for visual neuroscience researchers to access affordable and more sensitive OKR, contrast sensitivity (CS) and visual acuity (VA) assays. Here, we demonstrate how 2D- and 3D-printed, striped patterns or drums coupled with a motorised base and microscope provide a simple, cost-effective but efficient means to assay OKR, CS and VA in larval-juvenile zebrafish. ResultsIn wild-type, 5 days post-fertilisation (dpf) zebrafish, the 2D or 3D drums printed with the standard OKR stimulus of 0.02 cycles per degree (cpd), 100% black-white contrast evoked equivalent responses of 24.2 or 21.8 saccades per minute, respectively. Furthermore, although the OKR number was significantly reduced compared to the 0.02 cpd drum (p<0.0001), the 2D and 3D drums evoked respectively equivalent responses with the 0.06 and 0.2 cpd drums. Notably, standard OKR responses varied with time of day; peak responses of 29.8 saccades per minute occurred in the early afternoon with significantly reduced responses occurring in the early morning or late afternoon, (18.5 and 18.4 saccades per minute, respectively). A customised series of 2D printed drums enabled analysis of visual acuity and contrast sensitivity in 5-21 dpf zebrafish. The saccadic frequency in visual acuity and contrast sensitivity assays, was inversely proportional to age, spatial frequency and contrast of the stimulus. ConclusionsOKR, VA and CS of zebrafish larvae can be efficiently measured using 2D- or 3D-printed striped drums. For data consistency the luminance of the OKR light source, the time of day when the analysis performed, and the order of presentation of VA and CS drums must be considered. These simple methods allow effective and more sensitive analysis of functional vision in zebrafish.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 9
- FWCI
- 0.65
- Field percentile
- top 40%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Vertical Optokinetic Eye Movements in the Larval Zebrafish
David-Samuel Burkhardt, Gabriel Möller, … Aristides B. Arrenberg·Journal of Experimental BiologyPeer-reviewed·Jan 26, 2026
- Optimisation of OptoDrum protocol for measuring optomotor response in juvenile & adult zebrafish
Rebecca Super, Bang Viet Bui, … Patricia Regina Jusuf·bioRxiv·May 21, 2026
- A 3D-printed and freely available device to measure the zebrafish optokinetic response before and after injury
Ashley Hermans, Sophia Tajnai, … Steven J. Henle·bioRxiv·Aug 15, 2023
- Gaze stabilisation behaviour is anisotropic across visual field locations in zebrafish
Florian Alexander Dehmelt, Rebecca Meier, … Aristides B. Arrenberg·eLifePeer-reviewed·Jun 8, 2021
- Characterizing medaka visual features using a high-throughput optomotor response assay
Risa Suzuki, Jia Zheng Woo, … Tinatini Tavhelidse·PLoS ONEPeer-reviewed·Jun 28, 2024
- A Scalable, High-Throughput Optomotor Response Pipeline for Quantitative Analysis of Vision Using Infinity-Pools
Risa Suzuki, Damjan Kalšan, … Joachim Wittbrodt·bioRxiv·Jan 14, 2026