High sensitivity cameras can lower spatial resolution in high-resolution optical microscopy
Henning OrtkrassiD, Marcel W. MulleriD, Anders Kokkvoll EngdahliD, Gerhard Holst, Thomas R. HuseriD
Abstract
High-resolution optical fluorescence microscopies and, in particular, super-resolution fluorescence microscopy, are rapidly adopting highly sensitive cameras as their referred photodetectors. Camera-based parallel detection facilitates high-speed live cell imaging with the highest spatial resolution. Here, we show that the drive to use ever more sensitive, photon-counting image sensors in cameras can, however, have detrimental effects on spatial resolution that many researchers are not aware of. Typical parameters which influence the selection of image sensors are pixel size, quantum efficiency, signal-to-noise performance, dynamic range, and frame rate of the sensor. A parameter that is, however, often overlooked, is the sensors modulation transfer function (MTF). We have determined the wavelength-specific MTF of front- and back-illuminated image sensors and evaluated how it affects the spatial resolution that can be achieved in high fluorescence microscopy modalities. We find significant differences in image sensor performance for sensors that cause the resulting spatial resolution to vary with up to 28%. This result shows that the choice of image sensor has significant impact on the imaging performance of all camera-based optical microscopy modalities.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 7
- FWCI
- 0.67
- Field percentile
- top 41%
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Quantifying the spatio-temporal image degradation under motion blur in fluorescence microscopy
Serafim Korovin, Kutay Uğurlu, … Carlas Smith·Biophysical ReportsPeer-reviewed·Sep 23, 2026
- Nanoscopic resolution within a single imaging frame
Esley Torres, Raúl Pinto‐Cámara, … Adán Guerrero·bioRxiv·Oct 17, 2021
- Pixel-wise programmability enables dynamic high-SNR cameras for high-speed microscopy
Jie J. Zhang, Jonathan P. Newman, … Matthew A. Wilson·Nature CommunicationsPeer-reviewed·May 27, 2024
- Fluorescence fluctuation based super resolution microscopy, basic concepts for an easy start.
Alma Alva, Eduardo Brito‐Alarcón, … Adán Guerrero·Journal of MicroscopyPeer-reviewed·Jul 27, 2022
- Quantitative comparison of camera technologies for cost-effective Super-resolution Optical Fluctuation Imaging (SOFI)
R. Van den Eynde, A. Sandmeyer, … M. Mueller·bioRxiv·Apr 8, 2019
- Large field of view fluorescence imaging of microfluidic devices with a tandem-lens macroscope
Daniel Alexander Mokhtari, Ali Lashkaripour, Polly Morrell Fordyce·Lab on a ChipPeer-reviewed·Jan 1, 2026