The spatial resolution of optical imaging systems is fundamentally restricted by the diffraction limit. However, in widefield live-cell microscopy, the achievable resolution is further constrained by the specimen motion, which indicates the existence of a fundamental spatio-temporal resolution trade-off between signal accumulation during the full frame integration and the resulting motion blur. To improve the fidelity with which moving objects can be imaged, a quantitative understanding of this spatio-temporal trade-off is necessary. Here, we present a systematic analysis of motion-induced resolution dynamics measured with spectral signal-to-noise ratio (SSNR). We developed a simulation framework which models the image formation of objects undergoing arbitrary motion, to evaluate the degradation of the spatial resolution under translational and rotational dynamics. Our results demonstrate that for translating objects, the spatial resolution is anisotropically reduced as a function of the orientation of the object relative to the motion vector, leading to the spectral signal-to-noise ratio degrading by up to 50% and the resolution by up to 40% for a 90{degrees} change in the motion direction. Furthermore, we show that for rotational motion, conventional radially averaged metrics such as the Fourier Ring Correlation are not able to quantify the effects of angular blur. On the other hand, the SSNR is able to accurately quantify this degradation. These findings underscore the necessity of an object-oriented imaging approach, in which acquisition parameters such as exposure time are tuned to specific biological spatio-temporal characteristics to optimize the trade-off between motion blur and spatial fidelity.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- top 33%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High sensitivity cameras can lower spatial resolution in high-resolution optical microscopy
Henning Ortkrass, Marcel W. Muller, … Thomas R. Huser·Nature CommunicationsPeer-reviewed·Oct 15, 2024
- Fluorescence fluctuation based super resolution microscopy, basic concepts for an easy start.
Alma Alva, Eduardo Brito‐Alarcón, … Adán Guerrero·Journal of MicroscopyPeer-reviewed·Jul 27, 2022
- Nanoscopic resolution within a single imaging frame
Esley Torres, Raúl Pinto‐Cámara, … Adán Guerrero·bioRxiv·Oct 17, 2021
- Obtaining super-resolved images at the mesoscale through Super-Resolution Radial Fluctuations
Mollie Brown, Shannan Foylan, … Gail McConnell·Journal of Biomedical OpticsPeer-reviewed·Dec 24, 2024
- Innovative Strategies for Enhancing Signal-to-Noise Ratio in Single-molecule Imaging: The Influence of Molecular Motion
Gayun Bu, Gyeongho Kang, … Jong‐Bong Lee·bioRxiv·Oct 13, 2024
- Noise-robust, physical microscopic deconvolution algorithm enabled by multi-resolution analysis regularization