henhaobio
Sign in

bioRxivScientific Communication & Education

Democratizing access to microfluidics: Rapid prototyping of open microchannels with low-cost LCD 3D printers

K. M. Leong, A. Y. Sun, M. L. Quach, C. H. Lin, C. A. Craig, F. Guo, T. R. Robinson, M. M. Chang, A. O. Olanrewaju

PDFDOIPreprint

Abstract

Microfluidics offer user-friendly liquid handling for a range of biochemical applications. 3D printing microfluidics is rapid and cost-effective compared to conventional cleanroom fabrication. Typically, microfluidics are 3D printed using digital light projection (DLP) stereolithography (SLA), but many models in use are expensive ([≥]$10,000 USD), limiting widespread use. Recent liquid crystal display (LCD) technology advancements have provided inexpensive (<$500) SLA 3D printers with sufficient pixel resolution for microfluidic applications. However, there are only a few demonstrations of microfluidic fabrication, limited validation of print fidelity, and no direct comparisons between LCD and DLP printers. We compared a 40 {micro}m pixel resolution DLP printer ([~]$18,000 USD) with a 34.4 {micro}m (<$380) LCD-SLA printer. Consistent with prior work, we observed linear trends between designed and measured channel widths [≥] 4 pixels on both printers, so we calculated accuracy above this size threshold. Using a standard IPA wash resin and optimized parameters for each printer, the average error between designed and measured widths was 2.11 {+/-} 1.26% with the DLP printer and 15.4 {+/-} 2.57% with the 34.4 {micro}m LCD printer. The average coefficient of variation [CV] was [~]2% for both printers. Printing with optimized conditions for a low-cost water wash resin designed for LCD-SLA printers resulted in an average error of 2.53 {+/-} 0.94% with the 34.4 {micro}m LCD printer and 5.35 {+/-} 4.49% with a 22 {micro}m LCD printer. We characterized additional parameters including surface roughness, channel perpendicularity, and light intensity uniformity, and as an application of LCD-printed devices, we demonstrated consistent flow rates in capillaric circuits for self-regulated and self-powered delivery of multiple liquids. In conclusion, LCD printers are an inexpensive alternative for fabricating microfluidics, with minimal differences in fidelity and accuracy compared with a 20X more expensive DLP printer.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.