bioRxivBiophysicsPreprint
DNA double-strand break yield and radiation quality of diagnostic X-rays from 40 to 120 kV: a scale-resolved microdosimetric and track-structure study
Abstract
Reported relative biological effectiveness (RBE) values for low-energy X-rays disagree, assays scoring initial DNA double-strand breaks (DSBs) returning about 1.1 and chromosome-level assays 2 to 4. Whether radiation quality varies within the diagnostic range, and how its comparison with a megavoltage reference depends on target scale, has not been quantified on a tube-potential series. A tungsten-anode tube with 1 mm Be and 2.5 mm Al filtration, with copper added in some cases, was modelled in PHITS for 40 to 200 kV. The spectra were transported into a water phantom in which absorbed dose, lineal-energy densities and cluster size distributions were scored for target diameters of 3 nm to 1 micrometre against a cobalt-60 reference; DSB yields were computed in the electron track-structure mode with the PHITS DNA damage tally. Between 40 and 120 kV the depth-dose ratio changed by a factor of 5.7 and the tube output by a factor of 42, whereas the dose-mean lineal energy varied by 2.5 % at 1 micrometre and 1.2 % at 3 nm against a reproducibility of 0.3 %. Relative to cobalt-60 it was 2.05 times larger at 1 micrometre but only 1.08 times larger at 3 nm, while DSB yields per unit dose were 5 to 7 % higher and constant across the range within the 2 % bound set by the statistics. Tube potential therefore changes the amount and distribution of dose but not its physical quality, and a stated RBE is incomplete without the target scale implied by the endpoint.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Increased Relative Biological Effectiveness of Orthovoltage X-rays Compared to γ-rays in Preclinical Irradiation
B. I. Bell, J. Vercellino, … C. Guha·bioRxiv·Feb 18, 2022
- Third-generation dual-source computed tomography of the abdomen: comparison of radiation dose and image quality of 80kVp and 80/150kVp with tin filter
S. J. Choi, S. H. Park, … B. Kim·PLOS ONEPeer-reviewed·Sep 3, 2020
- 3D printed microtissue cassettes enabling high throughput proton radiobiological assays
Chih‐Tsung Yang, I-Chun Cho, … Benjamin Thierry·Analytica Chimica ActaPeer-reviewed·Apr 8, 2025
- DNA break clustering inside repair domains predicts cell death and mutation frequency in human fibroblasts and in Chinese hamster cells for a 10^3x range of linear energy transfers
E. Pariset, I. Plante, … S. V. Costes·bioRxiv·Nov 30, 2020
- Kinetics of radiation-induced DNA double-strand breaks through coarse-grained simulations
M. Micheloni, L. Petrolli, … R. Potestio·bioRxiv·Jul 3, 2022
- Cell lines of the same anatomic site and histologic type show large variability in intrinsic radiosensitivity and relative biological effectiveness to protons and carbon ions
D. B. Flint, S. J. Bright, … G. O. Sawakuchi·bioRxiv·Jun 19, 2020