bioRxivNeurosciencePreprint
Carbonized rubber electrodes can cause a DC-offset in transcranial alternating current stimulation
Heiko I. StecheriD, Peppi SchulziD, Arnd MeiseriD, Alexander HunoldiD, Klaus SchellhorniD, Christoph Siegfried HerrmanniD
Abstract
IntroductionCarbonized rubber electrodes are widely used in non-invasive brain stimulation studies. Due to their polarizable nature, however, they can cause a voltage offset, which might be problematic for concurrent EEG studies. ObjectiveIn this study, we aim to describe the voltage offset and ensure that the offset does not alter the intended waveform of applied stimulation. MethodsUsing data from 2 human studies and phantom measurements, which employed carbonized rubber electrodes, we quantify the magnitude and frequency of DC-offsets and contrast this against pilot-measurements using Ag/AGCl-electrodes. In a further phantom study, we record the offset-voltage that arises from the electrode/electrolyte interface and compare this to the voltage put out by the stimulation device. ResultsA non-zero voltage offset is present in all human and phantom studies employing carbonized rubber electrodes, while the offset using Ag/AgCl electrodes is close to zero. Direct measurements of the stimulator output in the presence of a measurable voltage offset at the stimulation electrodes shows that the offset originates from the electrodes and not from the current provided by the stimulation device. ConclusionUsing carbonized rubber-electrodes for stimulation can result in the emergence of a measurable voltage offset, due to their polarizable nature. We argue that this offset can be problematic in concurrent EEG recordings, as they pose the risk of amplifier saturation and distortions of the recorded stimulation waveform.
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Electrical Fields Induced Inside the Rat Brain with Skin, Skull, and Dural Placements of the Current Injection Electrode
Ahmet S. Asan, Sinan Gok, Mesut Şahin·PLoS ONEPeer-reviewed·Jan 10, 2019
- Inkjet-printed transparent electrodes for electrical brain stimulation
Rita Matta, Davide Reato, … Rodney Philip O'Connor·PLoS ONEPeer-reviewed·Apr 1, 2025
- Focal electrical stimulation on an alcohol disorder model using MRI-compatible chronic neural monopolar carbon fiber electrodes.
Alejandra López-Castro, Diego Ángeles-Valdéz, … Eduardo A. Garza‐Villarreal·bioRxiv·May 16, 2022
- Stimulation of the Dorsal Root Ganglion using an Injectrode
A. N. Dalrymple, J. E. Ting, … D. J. Weber·bioRxiv·Aug 16, 2021
- Epidural Spinal Cord Recordings (ESRs): Sources of Artifact in Stimulation Evoked Compound Action Potentials
Ashlesha Deshmukh, Megan L. Settell, … Kip A. Ludwig·bioRxiv·May 17, 2024
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter?
D. Q. Truong, A. Guillen, … A. Datta·bioRxiv·Aug 17, 2022