The effect of acquisition resolution on orientation decoding from V1: comparison of 3T and 7T
Ayan SenguptaiD, Oliver SpeckiD, Renat YakupoviD, Martin Kanowski, Claus TempelmanniD, Stefan PollmanniD, Michael HankeiD
Abstract
Previously published results indicate that the accuracy of decoding visual orientation from 7T fMRI data of V1 peaks at spatial acquisition resolutions that are routinely accessible with more conventional 3T scanners. This study directly compares the decoding performance between a 3T and a 7T dataset that were acquired using the same stimulation paradigm by applying an identical analysis procedure. The results indicate that decoding models built on 3T data are comparatively impaired. Moreover, we found no evidence for a strong coupling of BOLD signal change magnitude or temporal signal to noise ratio (tSNR) with decoding performance. Direct enhancement of tSNR via multiband fMRI acquisition at the same resolution did not translate into improved decoding performance. Additional voxel selection can boost 3T decoding performance to the 7T level only at a 3mm acquisition resolution. In both datasets the BOLD signal available for orientation decoding is spatially broadband, but, consistent with the size of the BOLD point-spread-function, decoding models at 3T utilize spatially coarser image components.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The effect of acquisition resolution on orientation decoding from V1 BOLD fMRI at 7 Tesla
Ayan Sengupta, Renat Yakupov, … Michael Hanke·NeuroImagePeer-reviewed·Mar 1, 2017
- Local opposite orientation preferences in V1: fMRI sensitivity to fine-grained pattern information
Arjen Alink, Alexander Walther, … Nikolaus Kriegeskorte·bioRxiv·Jan 10, 2016
- TDM: a temporal decomposition method for removing venous effects from task-based fMRI
Kendrick Kay, Keith Wakefield Jamison, … Kǎmil Uǧurbil·Nature MethodsPeer-reviewed·Sep 7, 2020
- Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Lars Kasper, Maria Engel, … Klaas P. Pruessmann·NeuroImagePeer-reviewed·Nov 17, 2021
- Capturing early human memory consolidation utilizing the higher functional specificity of 7T compared to 3T-fMRI
Silke Kreitz, Angelika Mennecke, … Andreas Heß·bioRxiv·Feb 1, 2022
- Spatial specificity of the functional gradient echo and spin echo BOLD signal across cortical depth at 7 T
Daniel Haenelt, Robert Trampel, … Nikolaus Weiskopf·bioRxiv·Jul 28, 2025