NeuroImageNeurosciencePeer-reviewed journal article
Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Lars KasperiD, Maria EngeliD, Jakob HeinzleiD, Matthias Müller-SchraderiD, Nadine N. GraedeliD, Jonas ReberiD, Thomas Schmid, Christoph BarmetiD, Bertram J. WilmiD, Klaas Enno StephaniD, Klaas P. PruessmanniD
- Citations
- 39
- FWCI
- 3.96
- Field percentile
- top 5%
Abstract
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination. HighlightsO_LIThis work reports the first fMRI study at 7T with high-resolution spiral readout gradient waveforms. C_LIO_LIWe achieve spiral fMRI with sub-millimeter resolution (0.8 mm, FOV 230 mm), acquired in a single shot (36 slices in 3.3 s). C_LIO_LISpiral images exhibit intrinsic geometric congruency to anatomical scans, and spatially specific activation patterns. C_LIO_LIImage reconstruction rests on a signal model expanded by measured trajectories and static field maps, inverted by cg-SENSE. C_LIO_LIWe assess generalizability of the approach for spiral in/out readouts, providing two images per shot (1.5 mm resolution). C_LI
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Feasibility of spiral fMRI based on an LTI gradient model
Nadine N. Graedel, Lars Kasper, … S. Johanna Vannesjo·NeuroImagePeer-reviewed·Oct 28, 2021
- Thermal Stimulus Task fMRI in the Cervical Spinal Cord at 7 Tesla
A. C. Seifert, J. Xu, … S. J. Vannesjo·bioRxiv·Jan 31, 2023
- Integration of a radiofrequency coil and commercial field camera for ultra-high-field MRI
K. M. Gilbert, P. Dubovan, … C. A. Baron·bioRxiv·Sep 27, 2021
- Spatial specificity of the functional gradient echo and spin echo BOLD signal across cortical depth at 7 T
Daniel Haenelt, Robert Trampel, … Nikolaus Weiskopf·bioRxiv·Jul 28, 2025
- Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans
Benedetta Franceschiello, Simone Rumac, … Eleonora Fornari·bioRxiv·May 13, 2023
- An optimized framework for simultaneous EEG-fMRI at 7T enabling safe, high-quality human brain imaging with millisecond temporal resolution and sub-millimeter spatial resolution
Cristina Sainz Martinez, Jonathan Wirsich, … João Jorge·bioRxiv·Aug 23, 2024