Improved EPR sensitivity for aqueous biological samples using low-volume multi-channel cells and dielectric resonators
Richard R. Mett, Alexander M. GarcesiD, Anand Anilkumar, Joseph T. Wehrley, Michael T. LerchiD, Candice S. KlugiD, Jason W. SidabrasiD
Abstract
Reducing sample volumes for electron paramagnetic resonance (EPR) spectroscopy applications places increasing demands on hardware design to preserve or enhance EPR signal intensity. In this work, the design, fabrication, and testing of dielectric resonators and multi-channel aqueous sample cells for applications in X-band (nominally 9.5 GHz) EPR is presented. Our aim was to maximize the EPR signal intensity for sample sizes of 3-4 L and 200 nL. These advances are summarized as follows: single-crystal sapphire and rutile dielectric resonators with very low loss tangent and high resonator efficiency; minimum dielectric resonator coupling to radiation shield to reduce ohmic losses; 3D printed aqueous sample cells with thin multi-channel construction to minimize radio-frequency dissipation in the sample; and a Gordon coupler for maximum coupling range and minimum stored energy to eliminate frequency shifts during tuning. Sample cell geometries were designed by leveraging insights gained from analytic theory to inform finite-element modeling of electromagnetic fields. Experimental comparisons of multi-channel sample cells using a sapphire resonator exhibited a 2.2-fold increase in EPR signal intensity compared with a standard capillary at 3-4 L, while simulations predict an additional 23% improvement with further 3D printing advances. For samples at 200 nL, a rutile dielectric resonator with a multi-channel sample cell was simulated to improve EPR sensitivity by a 2.7-fold increase compared with a capillary at the same volume.
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Ultra-precision 3D Printed Sample Tubes of Complex Cross Section for Enhanced Electron Paramagnetic Resonance Sensitivity of AqueousSamples
Anand Anilkumar, Joseph T Wherley, … Jason W. Sidabras·bioRxiv·Nov 2, 2026
- A High-Sensitivity Stopped-Flow EPR System to Monitor Millisecond Conformational Kinetics in Spin-Labeled Proteins
Alexander M. Garces, Richard R. Mett, … Michael T. Lerch·Protein SciencePeer-reviewed·Jul 16, 2025
- Electrochemical guided mode resonance biosensor for simultaneous refractive index and electrochemical measurements
Stephen Thorpe, Samuel F. J. Blair, … Steven Johnson·bioRxiv·Jul 16, 2025
- The Systematic Optimization of Square Wave Electroporation for Six Commonly Used Human Cell Lines
C. D. Vieira, T. Nesmith, … G. D. Gupta·bioRxiv·May 3, 2022
- Taguchi Design of Experiment for Optimizing Saline Solution Composition to Increase Electrical Coupling in a Multi-Electrode External EEG Sensor
Amishi Guliani, Prachi Tyagi, Pawan Tyagi·bioRxiv·Sep 21, 2025
- The Influence of Irreversibly Electroporated Cells on Post Pulse Drug Delivery to Reversibly Electroporated Cells
S. M. Becker·bioRxiv·Jun 23, 2021