Journal of BiomechanicsBioengineeringPeer-reviewed journal article
Community Challenge towards Consensus on Characterization of Biological Tissue: C4Bio's First Findings
Nele FamaeyiD, Heleen FehervaryiD, Yoann LafoniD, Ali Cagdas AkyildiziD, Silke DreeseniD, Karine Bruyère-GarnieriD, Jean‐Marc AllainiD, Marta AlloisioiD, Alejandro Aparici-GiliD, Chiara CatalanoiD, Fanette ChassagneiD, Snehal K. Chokhandre, Kimberly Crevits, Hanneke CrielaardiD, Eoghan M. CunnaneiD, Connor V. CunnaneiD, Karen De Leener, Amisha Desai, Rob C. H. DriesseniD, Ahmet Erdemir, Mona EskandariiD, Sam Evans, Christian Gasser, Marc GebhardtiD, Birgit GlasmacheriD, , Liesbet GerisiD
Abstract
This study investigates methodological variability across various expert laboratories worldwide, with regards to characterizing the mechanical properties of biological tissues. Two testing rounds were conducted on the specific use case of uniaxial tensile testing of porcine aorta. In the first round, 24 labs were invited to apply their established methods to assess inter-laboratory variability. This revealed significant methodological diversity and associated variability in the stress-stretch results, underscoring the necessity for a standardized approach. In the second round, a consensus protocol was collaboratively developed and adopted by 19 labs in an attempt to minimize variability. This involved standardized sample preparation and uniformity in testing protocol, including the use of a common cutting and thickness measurement tool. Despite protocol harmonization, significant variability persisted across labs, which could not be solely attributed to inherent biological differences in tissue samples. These results illustrate the challenges in unifying testing methods across different research settings, underlining the necessity for further refinement of testing practices. Enhancing consistency in biomechanical experiments is pivotal when comparing results across studies, as well as when using the resulting material properties for in silico simulations in medical research.
- Citations
- 13
- FWCI
- 3.14
- Field percentile
- top 7%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mechanical characterization of soft biomaterials: which time and spatial scale to choose?
Ekaterina S. Krivega, Svetlana Kotova, … Yuri M. Efremov·Soft MatterPeer-reviewed·Jan 1, 2024
- The MAASWERP study: An international, comparative case study on measuring biomechanics of the aged murine aorta
Cedric H. G. Neutel, Koen W.F. van der Laan, … Bart Spronck·PulsePeer-reviewed·Nov 25, 2024
- Evaluating sources of technical variability in the mechano-node-pore sensing pipeline and their effect on the reproducibility of single-cell mechanical phenotyping
B. Li, K. L. Cotner, … L. L. Sohn·bioRxiv·Jun 2, 2021
- Cross-Platform Mechanical Characterization of Lung Tissue
S. R. Polio, A. N. Kundu, … S. R. Peyton·bioRxiv·May 16, 2018
- Approach to standardized material characterization of the human lumbopelvic system - Testing and evaluation
Marc Gebhardt, Sascha Kurz, … Hanno Steinke·BioengineeringPeer-reviewed·Aug 11, 2025
- Capturing Regional Variation in Aortic Mechanics: Dual-Estimation Method for Material Parameter Identification and Biological Correlation
Ricardo Doll Lahuerta, Ayumi A. Miyakawa, … Idagene A. Cestari·Proceedings of the Royal Society A Mathematical Physical and Engineering SciencesPeer-reviewed·Sep 9, 2026