Using pressure-driven flow systems to evaluate laser speckle contrast imaging
C. T. Sullender, A. Santorelli, L. M. Richards, P. K. Mannava, C. Smith, A. K. Dunn
Abstract
SignificanceMicrofluidic flow phantom studies are commonly used for characterizing the performance of laser speckle contrast imaging (LSCI) instruments. The selection of the flow control system is critical for the reliable generation of flow during testing. The majority of recent LSCI studies using microfluidics used syringe pumps for flow control. AimWe quantified the uncertainty in flow generation for a syringe pump and a pressure-regulated flow system. We then assessed the performance of both LSCI and multi-exposure speckle imaging (MESI) using the pressure-regulated flow system across a range of flow speeds. ApproachThe syringe pump and pressure-regulated flow systems were evaluated during stepped flow profile experiments in a microfluidic device using an inline flow sensor. The uncertainty associated with each flow system was calculated and used to determine the reliability for instrument testing. The pressure-regulated flow system was then used to characterize the relative performance of LSCI and MESI during stepped flow profile experiments while using the inline flow sensor as reference. ResultsThe pressure-regulated flow system produced much more stable and reproducible flow outputs compared to the syringe pump. The expanded uncertainty for the syringe pump was 8-20x higher than that of the pressure-regulated flow system across the tested flow speeds. Using the pressure-regulated flow system, MESI outperformed single-exposure LSCI at all flow speeds and closely mirrored the flow sensor measurements, with average errors of 4.6 {+/-} 2.6% and 15.7 {+/-} 4.6%, respectively. ConclusionsPressure-regulated flow systems should be used instead of syringe pumps when assessing the performance of flow measurement techniques with microfluidic studies. MESI offers more accurate relative flow measurements than traditional LSCI across a wide range of flow speeds.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Guidelines for obtaining an absolute blood flow index with laser speckle contrast imaging
S. Sunil, S. Zilpelwar, … D. D. Postnov·bioRxiv·Apr 2, 2021
- A quasi-analytic solution for real-time multi-exposure speckle imaging of tissue perfusion
C. B. Schaffer, D. A. Rivera·bioRxiv·Apr 20, 2023
- Dynamic Laser Speckle Imaging
D. D. Postnov, J. Tang, … D. A. Boas·bioRxiv·May 21, 2019
- Laser Speckle Orthogonal Contrast Imaging Calibration by Replicating Red Blood Cells Scattering Statistics with a Moving Reference Diffuser
Xavier Orlik, Aurélien Plyer, Elise Colin‐Koeniguer·PhotonicsPeer-reviewed·Jun 25, 2026
- In Depth Flow Inspection Using Dynamic Laser Speckle Temporal Statistics
M. Golberg, R. Califa, … Z. Zalevsky·bioRxiv·Jun 23, 2019
- Measuring Perfusion Pressure and Flow Resistance in a Microfluidic Device Using an External Optical System
Matthew C. Coughlin, Marie A. Floryan, … Mark F. Coughlin·Journal of Micro and Nano-ManufacturingPeer-reviewed·Apr 8, 2026