bioRxivBioengineering
Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas
T. Santini, S. Wood, N. Krishnamurthy, T. Martins, H. J. Aizenstein, T. S. Ibrahim
Abstract
Recently cleared by the FDA, 7 Tesla (7T) MRI is a rapidly growing technology that can provide higher resolution and enhanced contrast in human MRI images. However, the increased operational frequency (~297 MHz) hinders its full potential since it causes inhomogeneities in the images and increases the power deposition in the tissues. This work describes the optimization of an innovative radiofrequency (RF) head coil coupled design, named Tic Tac Toe, currently used in large scale human MRI scanning at 7T; to date, this device was used in more than 1,300 patient/volunteer neuro 7T MRI scans. Electromagnetic simulations were performed for each of the coils antennas using the finite-difference time-domain method. Numerical optimizations were used to combine the calculated electromagnetic fields produced by these antennas, based on the superposition principle, and successfully produced homogeneous magnetic field distributions at low levels of power deposition in the tissues. The simulations were then successfully validated in-vivo using the Tic Tac Toe RF head coil system on a 7T MRI scanner.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
N. L. Rios, K. M. Gilbert, … J. Cohen-Adad·bioRxiv·Feb 8, 2023
- RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5 Tesla
Matt Waks, Russell Lagore, … Kǎmil Uǧurbil·bioRxiv·May 23, 2024
- Integration of a radiofrequency coil and commercial field camera for ultra-high-field MRI
K. M. Gilbert, P. Dubovan, … C. A. Baron·bioRxiv·Sep 27, 2021
- Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T
E. Kazemivalipour, A. Sadeghi-Tarakameh, … L. G. Rad·bioRxiv·Dec 13, 2022
- A 128-channel receive array with enhanced SNR performance for 10.5 tesla brain imaging
Russell Lagore, Alireza Sadeghi‐Tarakameh, … Kǎmil Uǧurbil·bioRxiv·Oct 20, 2024
- Personalized electric field simulations of deformable large TMS coils based on automatic position and shape optimization
Torge Worbs, Bianka Rumi, … Axel Thielscher·bioRxiv·Dec 27, 2024