A methodology to reduce the localization error in multi-loci microscopy provides new insights into enhancer biology
Abstract
Numerous functions hinge on the spatial dynamics of different genomic loci. Hence, microscopy techniques, such as chromatin tracing, have been developed to localize multiple loci in living and fixed cells. Depending on the throughput and specifics of the experiment, localization errors can still obscure the true spatial locations. We have developed a post-processing methodology to address this challenge without the need for additional experimentation: Loci Enabled Advanced Resolution (LEAR). By leveraging the fact that localization errors increase the variability of the displacements between loci, and given an approximation of the localization error, we can determine the ground truth spatial variation for each pair of loci to guide an iterative error correction process. After validating our approach with simulation and experiment, we then applied our approach to existing chromatin tracing data that probed the relation between chromatin organization and Sox2 regulation, where previous work found no correlation between enhancer-promoter proximity and transcription bursts in individual cells. We discovered a correlation previously obscured by localization error, clearly demonstrating the need for the methodology. We then investigated the influence of loop-extrusion on higher order multi-way contact frequencies, which dramatically increased with the application of the LEAR method, finding that certain multi-way contacts were only present with loop-extrusion.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 2
- FWCI
- 0.60
- Field percentile
- top 35%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Coarse-grained chromatin dynamics by trackingmultiple similarly labeled gene loci
Alexander Mader, Andrew I. Rodriguez, … S. G. J. Mochrie·Biophysical JournalPeer-reviewed·May 13, 2025
- Loop extrusion creates rare, long-lived encounters underlying enhancer-promoter communication
Mattia Alberto Ubertini, Nessim Louafi, … Luca Giorgetti·bioRxiv·Sep 24, 2025
- Nanometric axial localization of single fluorescent molecules with modulated excitation
P. Jouchet, C. Cabriel, … S. LEVEQUE-FORT·bioRxiv·Dec 5, 2019
- Sub-diffraction error mapping for localization microscopy images
R. J. Marsh, I. Costello, … S. Cox·bioRxiv·Feb 10, 2021
- Correlation Single Molecule Localization Microscopy (corrSMLM) Detects Fortunate Molecules for Better Localization Precision and High Signal-to-Noise Ratio
A. S, F. C. Zanacchi, P. P. Mondal·bioRxiv·Dec 29, 2022
- Sub-Nanometer Precision using Bayesian Grouping of Localizations
M. Fazel, M. J. Wester, … K. A. Lidke·bioRxiv·Aug 30, 2019