Magnetic Resonance in MedicineBioengineeringPeer-reviewed journal article
MR Spectroscopy without Water Suppression using the Gradient Impulse Response Function
Abstract
PurposeNon-water-suppressed proton spectroscopy, 1H-MRS, is desirable, as retaining the strong water resonance can facilitate automated online data corrections, internal concentration referencing, and monitoring of line narrowing effects in functional MRS. Removal of the water suppression module can also mitigate magnetization transfer effects and slightly reduce the minimum achievable TR and total RF power deposition. However, water suppression is typically considered essential due to eddy current-induced antisymmetric sidebands on the water resonance that distort the spectral baseline and obscure metabolite signals. Theory and MethodsThe Gradient Impulse Response Function (GIRF) was used to predict time-dependent magnetic field perturbations during the FID that generate the artefactual sidebands. The GIRF was measured in a one-time calibration, independent of spectroscopy acquisitions, enabling post-processing correction of the sidebands without sequence modification or additional dedicated hardware. GIRF-corrected non-water-suppressed single-voxel-spectroscopy (SVS) was compared to otherwise identical water-suppressed acquisitions in eight participants at 3T using semi-LASER and MEGA-PRESS sequences. ResultsAcross participants, GIRF correction reduced sideband amplitudes to levels comparable with the spectral baseline, enabling recovery of the underlying metabolite signals. Systematic increases in quantified metabolite concentrations were observed relative to water-suppressed acquisitions, consistent with water-suppression-induced magnetization transfer effects. Total creatine exhibited the largest increase, with enhancement ratios of 1.069{+/-}0.039 for MEGA-PRESS and 1.535{+/-}0.160 for semi-LASER acquisitions. ConclusionGradient-induced artefactual sidebands in non-water-suppressed MR spectroscopy can be effectively corrected using the GIRF to predict time-dependent magnetic field perturbations during the FID. In principle, the approach extends to other SVS sequences and field strengths following appropriate GIRF calibration.
- Citations
- 1
- FWCI
- 4.67
- Field percentile
- top 7%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla
Alex A. Bhogal, Tommy A.A. Broeders, … Jannie P. Wijnen·Brain and BehaviorPeer-reviewed·Nov 20, 2020
- Impacts of retrospective lipid suppression on metabolite quantification in preclinical proton MR spectroscopic imaging
Phan Tan Toi, Brayan Alves, … Cristina Cudalbu·bioRxiv·Sep 21, 2026
- Quantitative T1-relaxation corrected metabolite mapping of 12 metabolites in the human brain at 9.4 T
Andrew Martin Wright, Saipavitra Murali‐Manohar, A Henning·NeuroImagePeer-reviewed·Sep 1, 2022
- MRSIPrep: A Standardized Post-Quantification Framework for Preprocessing Whole-Brain Magnetic Resonance Spectroscopic Imaging
Federico Lucchetti, Edgar Céléreau, … Paul Klauser·bioRxiv·Sep 16, 2026
- Evaluations of retrospective frequency and phase correction methods for single-voxel MR spectroscopy at 7T
Chu‐Yu Lee, Jia Xu, … Vincent A. Magnotta·bioRxiv·Sep 22, 2026
- Reducing SAR in 7T brain fMRI by circumventing fat suppression while removing the lipid signal through a parallel acquisition approach
Amir Seginer, Edna Furman‐Haran, … Rita Schmidt·Scientific ReportsPeer-reviewed·Jul 28, 2021