Agreement between the ventilated capsule and the KuduSmart(R) device for measuring sweating responses to passive heat stress and exercise
Abstract
The present study assessed agreement between the KuduSmart(R) device and the ventilated capsule (VC) technique for measuring: i) minute-averaged local sweat rate (LSR); ii) sweating onset; iii) thermosensitivity; and iv) steady-state LSR, during passive heat stress and exercise. On two separate occasions for each heat stress intervention, participants were either passively heated by recirculating hot water (49{degrees}C) through a tube-lined garment until rectal temperature increased 1{degrees}C over baseline (n=8), or walked on a treadmill for 60 minutes at a fixed rate of heat production (n=9). LSR of the forearm was concurrently measured with a VC and the KuduSmart(R) device secured within [~]2 cm. Mean body temperature was calculated as the weighted average between rectal (80%) and mean skin (20%) temperature. Using a ratio scale Bland-Altman analysis with the VC as the reference, the KuduSmart(R) device demonstrated systematic bias for minute-averaged LSR (1.19 [1.09, 1.28]) and steady-state LSR (1.16 [1.09,1.23]), however no bias for thermosensitivity (1.08 [1.00, 1.16]) or sweating onset (1.00 [1.00, 1.00]). Although poor agreement was observed for minute-averaged LSR (CV = 43.3%), more than 73% of all observations with the KuduSmart(R) device (n=2795) were within an absolute error of < 0.2 mg/cm2/min to the VC. The KuduSmart(R) device demonstrated acceptable agreement for steady-state LSR (CV = 19.5%) and thermosensitivity (CV = 21.7%), and almost perfect agreement for sweating onset (CV = 0.14%). Collectively, the KuduSmart(R) device may be a satisfactory in-field solution for assessing the sweating response to heat stress.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Five days of heat acclimation improves cardiovascular and thermoregulatory responses without altering renal stress biomarkers in endurance athletes
Daniel Snape, Barney G. Wainwright, … John O’Hara·PLoS ONEPeer-reviewed·Aug 11, 2026
- On the use of facial and neck cooling to improve indoor occupant thermal comfort in warm conditions
- Revisiting the Humidity Ramp Protocol for Assessing Human Heat Tolerance Limits
Faming Wang, Yi Xu, … Xiong Shen·bioRxiv·Nov 9, 2025
- Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-worn Sensor: Performance Characterization Study
Nathan Kowahl, Sooyoon Shin, … Ritu Kapur·bioRxiv·Apr 21, 2023
- Influence of sustained cognitive loading on finger circulatory and thermoperceptual responsiveness to localized cooling
Maaike I. Moes, Antonis Elia, … Michail E. Keramidas·Journal of NeurophysiologyPeer-reviewed·Jul 7, 2025
- Noise-referenced multi-shell diffusion-weighted imaging for regional cerebrospinal fluid thermometry
Christian Behler, M. Breakspear, … M. Fay·bioRxiv·Nov 3, 2026