bioRxivBioengineeringPreprint
The Future is 2D: Spectral-Temporal Fitting of Dynamic Magnetic Resonance Spectroscopy Data Provides Exponential Gains in Precision Over Conventional Approaches
Abstract
AO_SCPLOWBSTRACTC_SCPLOWO_ST_ABSPurposeC_ST_ABSMany MRS paradigms produce 2D spectral-temporal datasets, including diffusion-weighted, functional, hyperpolarized and enriched (13C, 2H) experiments. Conventionally, temporal parameters - such as T2, T1, or diffusion constants - are assessed by first fitting each spectrum independently, and subsequently fitting a temporal model (1D fitting). We investigated whether simultaneously fitting the entire dataset using a single spectral-temporal model (2D fitting) would improve the precision of the relevant temporal parameter. MethodsWe derived a Cramer Rao Lower Bound for the temporal parameters for both 1D and 2D approaches, for two experiments: A multi-echo (MTE) experiment, designed to estimate metabolite T2s; And a functional (fMRS) experiment, designed to estimate fractional change ({delta}) in metabolite concentrations. We investigated the dependence of the relative standard deviation of T2 in MTE and{delta} in fMRS. ResultsWhen peaks were spectrally distant, 2D fitting improved precision by approximately 20% relative to 1D fitting, regardless of the experiment and other parameter values. These gains increased exponentially as peaks drew closer. Dependence on temporal model parameters was weak to negligible. ConclusionOur results strongly support a 2D approach to MRS fitting where applicable, and particularly in nuclei such as 1H and 2H, which exhibit substantial spectral overlap.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Universal Dynamic Fitting of Magnetic Resonance Spectroscopy
William T. Clarke, Clémence Ligneul, … Saâd Jbabdi·Magnetic Resonance in MedicinePeer-reviewed·Jan 24, 2024
- Improving the reliability of T2 measurement in magnetic resonance imaging
Xiuli Yang·bioRxiv·Jun 9, 2024
- Magnetic Resonance Fingerprinting with Combined Gradient- and Spin-echo Echo-planar Imaging: Simultaneous Estimation of T1, T2 and T2* with integrated-B1 Correction
M. Khajehim, T. Christen, J. J. Chen·bioRxiv·Apr 10, 2019
- Time-efficient relaxation measurements by 31P MR fingerprinting in human brain at 7T
S.-I. Lim, M. S. Widmaier, … L. Xin·bioRxiv·May 23, 2022
- Model-based frequency-and-phase correction of 1H MRS data with 2D linear-combination modeling.
Dunja Simičić, Helge J. Zöllner, … Georg Oeltzschner·bioRxiv·Mar 26, 2024
- Fast in vivo 23Na imaging and T2* mapping using accelerated 2D-FID magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study
A. A. Alhulail, P. Xia, … U. E. Emir·bioRxiv·May 25, 2020