henhaobio
Sign in

bioRxivNeurosciencePreprint

Model-based frequency-and-phase correction of 1H MRS data with 2D linear-combination modeling.

Dunja SimičićiD, Helge J. ZöllneriD, Christopher W. Davies‐JenkinsiD, Kathleen E. HupfeldiD, Richard A.E. EddeniD, Georg OeltzschneriD

PDFDOI

Abstract

PurposeRetrospective frequency-and-phase correction (FPC) methods attempt to remove frequency- and-phase variations between transients to improve the quality of the averaged MR spectrum. However, traditional FPC methods like spectral registration struggle at low SNR. Here, we propose a method that directly integrates FPC into a two-dimensional linear-combination model (2D-LCM) of individual transients ( model-based FPC). We investigated how model-based FPC performs compared to the traditional approach, i.e., spectral registration followed by 1D-LCM in estimating frequency-and-phase drifts and, consequentially, metabolite level estimates. MethodsWe created synthetic in-vivo-like 64-transient short-TE sLASER datasets with 100 noise realizations at 5 SNR levels and added randomly sampled frequency and phase variations. We then used this synthetic dataset to compare the performance of 2D-LCM with the traditional approach (spectral registration, averaging, then 1D-LCM). Outcome measures were the frequency/phase/amplitude errors, the standard deviation of those ground-truth errors, and amplitude Cramer Rao Lower Bounds (CRLBs). We further tested the proposed method on publicly available in-vivo short-TE PRESS data. Results2D-LCM estimates (and accounts for) frequency-and-phase variations directly from uncorrected data with equivalent or better fidelity than the conventional approach. Furthermore, 2D-LCM metabolite amplitude estimates were at least as accurate, precise, and certain as the conventionally derived estimates. 2D-LCM estimation of frequency and phase correction and amplitudes performed substantially better at low-to-very-low SNR. ConclusionModel-based FPC with 2D linear-combination modeling is feasible and has great potential to improve metabolite level estimation for conventional and dynamic MRS data, especially for low-SNR conditions, e.g., long TEs or strong diffusion weighting.

Citations
3

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISShamaei '22Ma '21Zöllner '24Ma '23Lee '26Siviglia '26
72% semantic matchNeuroscience
Amirmohammad Shamaei, Jana Starčuková, Iveta Pavlova+1 more·Magnetic Resonance in Medicine·Nov 11, 2022· 23 citations