COEXIST: Coordinated single-cell integration of serial multiplexed tissue images
Robert T. HeussneriD, Cameron WatsoniD, Christopher EddyiD, Kunlun WangiD, Eric M. CrameriD, Allison CreasoniD, Gordon Brent MillsiD, Young Hwan ChangiD
Abstract
Multiplexed tissue imaging (MTI) and other spatial profiling technologies commonly utilize serial tissue sectioning to comprehensively profile samples by imaging each section with unique biomarker panels or assays. The dependence on serial sections is attributed to technological limitations of MTI panel size or incompatible multi-assay protocols. Although image registration can align serially sectioned MTIs, integration at the single-cell level poses a challenge due to inherent biological heterogeneity. Existing computational methods overlook both cell population heterogeneity across modalities and spatial information, which are critical for effectively completing this task. To address this problem, we first use Monte-Carlo simulations to estimate the overlap between serial 5m-thick sections. We then introduce COEXIST, a novel algorithm that synergistically combines shared molecular profiles with spatial information to seamlessly integrate serial sections at the single-cell level. We demonstrate COEXIST necessity and performance across several applications. These include combining MTI panels for improved spatial single-cell profiling, rectification of miscalled cell phenotypes using a single MTI panel, and the comparison of MTI platforms at single-cell resolution. COEXIST not only elevates MTI platform validation but also overcomes the constraints of MTIs panel size and the limitation of full nuclei on a single slide, capturing more intact nuclei in consecutive sections and thus enabling deeper profiling of cell lineages and functional states.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 5
- FWCI
- 1.49
- Field percentile
- top 19%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- COLLAGE: COnsensus aLignment of muLtiplexing imAGEs
Asier Antoranz, Alexandre Arnould, … Jon Pey·bioRxiv·Jul 15, 2024
- One Section, Two Worlds: Single-Cell Integration of MALDI-MSI and Spatial Transcriptomics on the Same Single Tissue Section
Tim Hendriks, Gert B. Eijkel, … Eva Cuypers·Scientific ReportsPeer-reviewed·Nov 28, 2025
- Spatial Integration of Multi-Omics Data using the novel Multi-Omics Imaging Integration Toolset
Maximillian Wess, Maria K. Andersen, … May‐Britt Tessem·bioRxiv·Jun 11, 2024
- Image-guided alignment of consecutive multi-modal tissue slides
Benedetta Manzato, Claudio Novella-Rausell, … Ahmed Essam Mahfouz·Cell Reports MethodsPeer-reviewed·Sep 1, 2026
- High-Parameter Spatial Multi-Omics through Histology-Anchored Integration
Yonghao Liu, Chuyao Wang, … Zhiyuan Yuan·Nature MethodsPeer-reviewed·Dec 17, 2025
- MCMICRO: A scalable, modular image-processing pipeline for multiplexed tissue imaging
Denis Schapiro, Artem Sokolov, … Peter Karl Sorger·Nature MethodsPeer-reviewed·Nov 25, 2021