bioRxivNeurosciencePreprint
In vivo quantification of creatine kinase kinetics in mouse brain using 31P-MRS at 7 Tesla
Mohamed TachrountiD, Sean SmartiD, Jason P. LerchiD, Antoine CherixiD
Abstract
31P-MRS is a method of choice for studying neuroenergetics in vivo, but its application in the mouse brain have been limited, often restricted to ultra-high field (>7 Tesla) MRI scanners. Establishing its feasibility on more readily available preclinical 7 Tesla (T) scanners would create new opportunities to study metabolism and physiology in murine models of brain disorders. Here, we demonstrate that the apparent forward rate constant (kf) of creatine kinase (CK) can be accurately quantified using a progressive saturation-transfer approach in the mouse brain at 7T. We also find that a reduction of approximately 20% in the breathing rate of anesthetized mice can lead to a 36% increase in kf attributable to a drop in intracellular pH and mitochondrial ATP production. To achieve this, we used a test-retest analysis to assess the reliability and repeatability of 31P-MRS acquisition, analysis and experimental design protocols. We report that most 31P-containing metabolites can be reliably measured using a localized 3D-ISIS sequence, which showed highest SNR amplitude, SNR consistency and minimal T2 relaxation signal loss. Using this protocol, our study identifies, for the first time, key physiological factors influencing mouse brain energy homeostasis in vivo and provides a methodological basis that will guide future studies interested in implementing 31P-MRS on preclinical 7T scanners.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)
W. T. Clarke, L. Hingerl, … C. T. Rodgers·bioRxiv·Dec 10, 2021
- Multi-site Ultrashort Echo Time 3D Phosphorous MRSI repeatability using novel Rosette Trajectory (PETALUTE)
Şeyma Alçiçek, Alexander R. Craven, … Uzay E. Emir·bioRxiv·Feb 7, 2024
- 31P Transversal Relaxation Times and Metabolite Concentrations in the Human Brain at 9.4T
Johanna Dorst, Tamás Borbáth, … A Henning·NMR in BiomedicinePeer-reviewed·May 24, 2022
- Time-efficient relaxation measurements by 31P MR fingerprinting in human brain at 7T
S.-I. Lim, M. S. Widmaier, … L. Xin·bioRxiv·May 23, 2022
- Metabolic clearance rate modeling: A translational approach to quantifying cerebral metabolism using hyperpolarized pyruvate.
J. T. Grist, N. Boegh, … C. Laustsen·bioRxiv·Nov 2, 2022
- Non-invasive measurement of neurotransmitter-specific glucose metabolism in the human brain using proton-observed proton-edited 13C-MRS (POPE13C-MRS)
Antoine Cherix, Oliver Härmson, … Charlotte Jane Stagg·bioRxiv·Jul 13, 2026