Evaluation of Diffusion Tensor Imaging in the Corpus Callosum on a Portable 100 mT MRI System
Philip Kenneth LeeiD, Suen CheniD, Sijie ZhongiD, Changyue WangiD, Zhiyong ZhangiD
Abstract
Low-cost portable MRI has the potential to improve the accessibility of MRI, but new acquisition methods and protocols must be developed and evaluated to accommodate the reduction in SNR and greater impact of system imperfections. Diffusion tensor imaging (DTI) is a candidate tool for monitoring population health, but the bias and variance of quantitative diffusion tensor-derived metrics must be evaluated prior to designing such studies. DTI of the corpus callosum was performed on an in-house, portable 100 mT MRI system using a slab diffusion weighted Fast Spin Echo with radiofrequency (RF) encoding. Slice coverage was restricted to the corpus callosum to shorten scan time and reduce sensitivity to large rigid motion. In vivo DTI images were obtained in two healthy volunteers with nominal voxel size 50 mm3, scan time 25 minutes, and two different volunteers using nominal voxel size 25 mm3, scan time 35 minutes. Mean diffusivity (MD) and fractional anisotropy (FA) coefficients of variation were estimated in the 50 mm3 acquisition using a bootstrap approach and compared to resolution-matched data obtained on a conventional 1.5T system. MD / FA maps were compared quantitatively and qualitatively. Mean MD values in the corpus callosum obtained on the 100 mT system were within 10% of the reference 1.5T acquisition, but FAs were underestimated by 20-30%. The corpus callosum median MD coefficient of variation was 3.7%, and the median FA coefficient of variation was 7.5%. FA maps obtained at 100 mT had an elevated FA noise floor and color FA maps had lower apparent resolution but some white matter tracts were still distinguishable. HighlightsO_LIDiffusion Tensor Imaging (DTI) of the corpus callosum was performed on a portable 100 mT MRI scanner with 50 mm3 voxels in 25 minutes scan time. C_LIO_LIMean Diffusivity estimates in the corpus callosum obtained at 100 mT and 1.5T differed by less than 0.1 x 10-3 mm2/s. C_LIO_LISome white matter tracts were visible in color Fractional Anisotropy maps obtained at 100 mT but FA maps were underestimated by 20- 30% when compared to a resolution-matched 1.5T acquisition, and had lower apparent resolution. C_LI
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- COnstrained Reference frame diffusion TEnsor Correlation Spectroscopic (CORTECS) MRI: A practical framework for high-resolution diffusion tensor distribution imaging
A. V. Avram, K. S. Saleem, P. J. Basser·bioRxiv·Oct 20, 2022
- In Utero Diffusion Tensor Imaging Of The Fetal Brain: A Reproducibility Study
Jakab András, Ruth Tuura, … Ianina Scheer·NeuroImage ClinicalPeer-reviewed·Jan 1, 2017
- Reproducibility and reliability of Free-Water-corrected Diffusion Tensor Imaging of the brain: Revisited
Tomasz Pieciak, Guillem París, … Antonio Tristán‐Vega·Human Brain MappingPeer-reviewed·Feb 15, 2026
- Precision Diffusion Imaging
Nicole A. Seider, Babatunde Adeyemo, … Nico U.F. Dosenbach·bioRxiv·Feb 19, 2021
- Diffusion Tensor Model links to Neurite Orientation Dispersion and Density Imaging at high b-value in Cerebral Cortical Gray Matter
Hikaru Fukutomi, Matthew F. Glasser, … Takuya Hayashi·Scientific ReportsPeer-reviewed·Aug 22, 2019
- High-frequency longitudinal white matter diffusion- & myelin-based MRI database: reliability and variability
Manon Edde, Guillaume Theaud, … Maxime Descoteaux·Human Brain MappingPeer-reviewed·Apr 17, 2023