Feasibility of spiral fMRI based on an LTI gradient model
Nadine N. GraedeliD, Lars KasperiD, Maria EngeliD, Jennifer NussbaumiD, Bertram J. WilmiD, Klaas P. PruessmanniD, S. Johanna VannesjoiD
Abstract
Spiral imaging is very well suited for functional MRI, however its use has been limited by the fact that artifacts caused by gradient imperfections and B0 inhomogeneity are more difficult to correct compared to EPI. Effective correction requires accurate knowledge of the traversed k-space trajectory. With the goal of making spiral fMRI more accessible, we have evaluated image reconstruction using trajectories predicted by the gradient impulse response function (GIRF), which can be determined in a one-time calibration step. GIRF-predicted reconstruction was tested for high-resolution (0.8 mm) fMRI at 7T. Image quality and functional results of the reconstructions using GIRF-prediction were compared to reconstructions using the delay-corrected nominal trajectory and concurrent field monitoring. The reconstructions using nominal spiral trajectories contain substantial artifacts and the activation maps contain misplaced activation. Image artifacts are substantially reduced when using the GIRF-predicted reconstruction, and the activation maps for the GIRF-predicted and monitored reconstructions largely overlap. The GIRF reconstruction provides a large increase in the spatial specificity of the activation compared to the nominal reconstruction. The GIRF-reconstruction generates image quality and fMRI results similar to using a concurrently monitored trajectory. The presented approach does not prolong or complicate the fMRI acquisition. Using GIRF-predicted trajectories has the potential to enable high-quality spiral fMRI in situations where concurrent trajectory monitoring is not available. HighlightsO_LIThis work investigates the feasibility of using a one-time system calibration to account for k-space trajectory deviations in spiral fMRI. C_LIO_LIThis versatile calibration is based on a linear time-invariant gradient model, the gradient impulse response function (GIRF). C_LIO_LIWe show that the image quality and the spatial specificity of the fMRI activation are substantially improved when using the GIRF-predicted trajectories. C_LIO_LIBasing reconstructions on nominal gradient inputs, on the other hand, induces image artifacts and misplaced fMRI activation. C_LIO_LIWe demonstrate that system characterization via the GIRF can enable spiral fMRI in situations where concurrent trajectory monitoring is unavailable. C_LI
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 11
- FWCI
- 0.92
- Field percentile
- top 28%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Lars Kasper, Maria Engel, … Klaas P. Pruessmann·NeuroImagePeer-reviewed·Nov 17, 2021
- Open-Source Framework for Measurement of the Gradient Impulse Response Function
James B Bacon, Rudy Rizzo, … William T. Clarke·bioRxiv·Aug 25, 2026
- Attenuation of Motion Artifacts in fMRI using Discrete Reconstruction of Irregular fMRI Trajectories (DRIFT)
David B. Parker, Pascal Spincemaille, Qolamreza Ray Razlighi·Magnetic Resonance in MedicinePeer-reviewed·Apr 1, 2021
- Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans
Benedetta Franceschiello, Simone Rumac, … Eleonora Fornari·bioRxiv·May 13, 2023
- Integration of a radiofrequency coil and commercial field camera for ultra-high-field MRI
K. M. Gilbert, P. Dubovan, … C. A. Baron·bioRxiv·Sep 27, 2021
- Fuzzy ripple artifact in high resolution fMRI: identification, cause, and mitigation
Laurentius Huber, Rüdiger Stirnberg, … Peter A. Bandettini·Magnetic Resonance in MedicinePeer-reviewed·Apr 2, 2025