Thermal Stimulus Task fMRI in the Cervical Spinal Cord at 7 Tesla
A. C. Seifert, J. Xu, Y. Kong, F. Eippert, K. L. Miller, I. Tracey, S. J. Vannesjo
Abstract
PurposeAlthough functional MRI is widely applied in the brain, fMRI of the spinal cord is more technically demanding. Proximity to the vertebral column and lungs results in strong spatial inhomogeneity and temporal fluctuations in B0. Increasing field strength enables higher spatial resolution and improved sensitivity to BOLD signal, but amplifies the effects of B0 inhomogeneity. In this work, we present the first task fMRI in the spinal cord at 7 T. Further, we compare the performance of single-shot and multi-shot 2D EPI protocols, which differ in sensitivity to spatial and temporal B0 inhomogeneity. MethodsThe cervical spinal cords of 11 healthy volunteers were scanned at 7 T using single-shot 2D EPI at 0.75 mm in-plane resolution and multi-shot 2D EPI at 0.75 and 0.6 mm in-plane resolutions. All protocols used 3 mm slice thickness. For each protocol, the BOLD response to thirteen 10-second noxious thermal stimuli applied to the right thumb was acquired in a 10-minute fMRI run. Image quality, temporal SNR, and BOLD activation (percent signal change and z-stat) at both individual-and group-level were evaluated between the protocols. ResultsTemporal SNR was highest in single-shot and multi-shot 0.75 mm protocols. In group-level analyses, activation clusters appeared in all protocols in the ipsilateral dorsal quadrant at the expected C6 neurological level. In individual-level analyses, activation clusters at the expected level were detected in some, but not all subjects and protocols. Single-shot 0.75 mm generally produced the highest mean z-statistic, while multi-shot 0.60 mm produced the best-localized activation clusters and the least geometric distortion. Larger than expected within-subject segmental variation of BOLD activation along the cord was observed. ConclusionGroup-level sensory task fMRI of the cervical spinal cord is feasible at 7 T with single-shot or multi-shot EPI. The best choice of protocol will likely depend on the relative importance of sensitivity to activation versus spatial localization of activation for a given experiment. HighlightsFirst stimulus task fMRI results in the spinal cord at 7 T Single-shot 0.75 mm 2D EPI produced the highest mean z-statistic Multi-shot 0.60 mm 2D EPI provided the best-localized activation and least distortion
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Reliability of task-based fMRI in the dorsal horn of the human spinal cord
Alice Dabbagh, Ulrike Horn, … Falk Eippert·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Lars Kasper, Maria Engel, … Klaas P. Pruessmann·NeuroImagePeer-reviewed·Nov 17, 2021
- Functional magnetic resonance imaging of the lumbosacral cord during a lower extremity motor task
Christian W. Kündig, Jürgen Finsterbusch, … Gergely Dávid·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Test-retest reliability of sensorimotor activity measured with spinal cord fMRI
Olivia S. Kowalczyk, Sonia Medina, … Matthew A. Howard·Human Brain MappingPeer-reviewed·Jun 29, 2026
- Impact of Autocalibration Method on Accelerated Echo-Planar Imaging of the Cervical Spinal Cord at 7T
A. C. Seifert, J. Xu·bioRxiv·Mar 8, 2022
- Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study
Eva Alonso‐Ortiz, Daniel Papp, … Julien Cohen‐Adad·Magnetic Resonance in MedicinePeer-reviewed·May 20, 2025